background image

10

  

1.2 I  Technical specifications

Standards

Defrost

Z200

M2

M3

M4

M5

MD2

MD3

MD4

MD5

PI20

PI2021 PI2031 PI2041 PI2051 PI2021D PI2031D PI2041D PI2051D

Power

5M

7M

9M

11M

Operating temperature range

air

5 to 32°C

- 5 to 32°C

water

up to 32°C

Operating power*

kW

4.5

6.4

7.9

9.7

4.8

7

8.1

10.1

Voltage

230V-50Hz

Defrosting by forced air circulation

X

X

X

X

Defrosting by cycle inversion

X

X

X

X

Acceptable variation in voltage

-10%, +7% (during operation)

Pollution class**

I

Pollution degree**

2

Overvoltage category**

II

Nominal absorbed intensity

A

4.5

6.3

7.9

11.2

4.5

6.3

7.9

11.2

Maximum absorbed intensity

A

5.2

7.6

10.2

13.4

5.2

7.6

10.2

13.4

Minimum cable section***

mm²

3x2,5

3G2,5

Proof pressure

bar

6

Service pressure

bar

1.5

Max. Discharge/Suction Pressure

bar

42/1.2

Max. high-pressure/low pressure 

side pressure

bar

42/1.2

Head loss

mCE

1

1.5

1

1.5

Minimum optimum water flow rate

m³/h

4

Maximum water flow 

m³/h

10

Refrigerant type

R32

Refrigerant charge

kg

0.68

0.85

0.9

1.1

0.68

0.8

0.9

1.1

Weight

kg

40

45

50

53

40

45

50

53

The appliances have an Ingress Protection (IP) rating of IPX4 or better. Please refer to the marking indicating the IP-rating 

on your particular product.

* Performance: air 15 °C / water 26 °C / humid. 70%.

** These characteristics have been determined from the requirements defined in IEC/EN 60335 and IEC/EN 60035-2-40 for the safety of household 

and similar electrical appliances.

*** Values provided for information purposes for a maximum length of 20 metres (calculation base: NFC15-100), must be checked and adapted to the 

installation conditions and standards of the installation country.

Содержание PI20 Series

Страница 1: ...H0548500_REVE 2020 02 More documents on www zodiac com Z200 PI20 Power Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Страница 2: ......

Страница 3: ...t they do not play with the appliance Cleaning and similar user maintenance shall not be made by children without adult supervision The appliance must be installed according to the manufacturer s inst...

Страница 4: ...ensure that it is switched off and completely disconnected from the power supply Furthermore in addition to confirming that the heating priority where applicable is deactivated ensure that any other e...

Страница 5: ...eratures in excess of 100 C and high pressures with the consequent risk of severe burns Area check Prior to beginning work on systems containing flammable refrigerants safety checks are necessary to e...

Страница 6: ...be reported to the owner of the equipment so all parties are advised Initial safety checks shall include that capacitors are discharged this shall be done in a safe manner to avoid possibility of spa...

Страница 7: ...to make repairs or for any other purpose conventional procedures shall be used However for flammable refrigerants it is important that best practice is followed since ammability Is a consideration The...

Страница 8: ...ified to do so Replacement pipes must always be made of copper in compliance with standard NF EN 12735 1 Leak detection pressure test never use oxygen or dry air risk of fire or explosion use dry nitr...

Страница 9: ...to prevent ignition in the event of a refrigerant release Consult manufacturer it in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder and...

Страница 10: ...t you read this installation and user manual as well as the Warranty booklet delivered with the device Failure to do so may result in material damage or serious or fatal injury and will invalidate the...

Страница 11: ...th plug except 11M C Joint x2 D Screw in connector x2 E 40 adaptation x2 F 50 reduction x2 G Condensation evacuation kit 15 H Winterizing cap x2 I Winterizing cover Heating priority Not compatible J R...

Страница 12: ...ervice pressure bar 1 5 Max Discharge Suction Pressure bar 42 1 2 Max high pressure low pressure side pressure bar 42 1 2 Head loss mCE 1 1 5 1 1 5 Minimum optimum water flow rate m h 4 Maximum water...

Страница 13: ...on valve and user interface Ventilator Technical access door Pool water intake Pool water output Evaporator Grommet for heating priority cable run Location for drilling for remote control cable run de...

Страница 14: ...ale is available on the back of the packaging carton front rear connectors Top view of the device with dimensions for attachment to the ground The device must not be installed In a closed and unventil...

Страница 15: ...to make it easier to work on the device water entry valve by pass valve water exit valve water entry adjustment valve optional water exit adjustment valve optional water treatment minimum distance To...

Страница 16: ...n plate The electricity supply cable must be insulated against any cutting or hot elements that may damage or crush it The equipment must be connected to an earth socket The electrical connection line...

Страница 17: ...mp power contactor coil filtration timer power contactor tripolar or bipolar for the filtration system pump motor separate cable for the heating priority function heat pump terminal see wiring diagram...

Страница 18: ...ing range sufficient to heat Cover the basin with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night your heat pum...

Страница 19: ...adually so that the filter pressure is increased by 150g 0 150 bars Open valves A C and D fully then valve E by half the air which has built up in the heat pump condenser and the filtration circuit wi...

Страница 20: ...the setpoint temperature is displayed fixed To read the water temperature it is imperative that the filtration is in operation and that the water flow indicator is fixed 3 4 2 Locking unlocking the k...

Страница 21: ...t on a yearly basis to ensure proper operation maintain performance levels and prevent some potential failures These operations are carried out at the user s expense by a technician 4 2 1 User mainten...

Страница 22: ...your heat pump cannot manage to deice its evaporator it will stop itself this means that the outdoor temperature is too low below 5 C for standard models 5 C for Defrost models The device is not worki...

Страница 23: ...temperature too high 32 C maximum Wait until the temperature falls Flow controller blocked Check the flow controller Water condenser scaled up or blocked Clean the water condenser Outside temperature...

Страница 24: ...p relay Earth KM4 Complementary relay C1 Compressor condenser M1 Compressor C2 Ventilator condenser M2 Ventilator CD Flow controller SD1 Water temperature sensor E1 High pressure switch SD2 Air temper...

Страница 25: ...KM4 Complementary relay C1 Compressor condenser M1 Compressor C2 Ventilator condenser M2 Ventilator CD Flow controller SD1 Water temperature sensor HP High pressure switch SD2 Air temperature sensor...

Страница 26: ......

Страница 27: ......

Страница 28: ...23 49180 St Barth l my d Anjou cedex S A S U au capital de 1 267 140 SIREN 395 068 679 RCS PARIS Votre revendeur Your retailer Mod le appareil Appliance model Num ro de s rie Serial number Pour plus d...

Отзывы: