background image

Page 3 

English

  

 

Jandy

®

 Pro Series, Slide Valve & Backwash Valve   

|

   Installation & Operation Manual

 WARning

FOR YOUR sAFETY

: This product must be installed and serviced by a professional pool/spa service technician. 

The procedures in this instruction sheet must be followed exactly. Improper installation and/or operation will void the 

warranty. 

 WARning

Ensure that all electrical power to the system is turned off before approaching, inspecting or troubleshooting any 

leaking valves that may have caused other electrical devices in the surrounding area to get wet. Failure to do so 

could result in an electrical hazard that could result in death or serious injury due to electrical shock, and may also 

cause damage to property and/or operation. 

section 1.  safety information

 

WARning

•  Do not connect system to an unregulated city water system or other external source of 

pressurized water producing pressures greater than 35 PSI.

•  Pressurized air in system can cause product failure or also cause the filter lid to be blown off 

which can result in death, serious personal injury, or property damage. Be sure all air is out 

of system before operating or testing the equipment.

 

WARning

To minimize risk of severe injury or death the filter and/or pump should not be subjected to the 

piping system pressurization test.
Local codes may require the pool piping system to be subjected to a pressure test. These 

requirements are generally not intended to apply to the pool equipment such as filters or pumps.
Jandy Pro Series pool equipment is pressure tested at the factory.
If however this WARNING cannot be followed and pressure testing of the piping system must include 

the filter and/or pump BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS:

•  Check all clamps, bolts, lids, lock rings and system accessories to ensure they are properly installed 

and secured before testing.

•  RElEAsE All AiR

 in the system before testing.

•  Water pressure for test must NOT EXCEED 35 PSI.
•  Water temperature for test must NOT EXCEED 100°F (38°C).
•  Limit test to 24 hours. After test, visually check system to be sure it is ready for operation.  

notice

: These parameters apply to Jandy Pro Series equipment only. For non-Jandy equipment, consult 

equipment manufacturer.

REAd And FOllOW All insTRUCTiOns

Содержание Jandy Pro Series

Страница 1: ...oduct read and follow all warning notices and instructions that accompany this product Failure to follow warning notices and instructions may result in property damage personal injury or death Imprope...

Страница 2: ...le of Contents Section 1 Safety Information 3 Section 2 SVLV8 Installation 4 Section 3 SVLV2 and Versa Coupler Installation 5 Section 4 Normal Operation 6 Section 5 Backwash Mode 6 Section 6 Servicing...

Страница 3: ...sult in death serious personal injury or property damage Be sure all air is out of system before operating or testing the equipment WARNING To minimize risk of severe injury or death the filter and or...

Страница 4: ...ration mode fully extend the valve handle See Figure 1 Section 2 SVLV8 Installation 1 Remove the Slide Valve from the packaging Twist the handle on the Slide Valve several times to verify that the pis...

Страница 5: ...tain filters may require only one 1 versa coupler p n 8044 1 Slide one 1 versa coupler into PORT C and one 1 into PORT D on the Slide Valve 2 Hold the Slide Valve up to the filter and twist the versa...

Страница 6: ...2 Open the air release valve on top of the filter tank to release all pressure from inside the tank and system Wait for all the air to evacuate the system 3 Jandy Pro Series DEL DEV and JS series Filt...

Страница 7: ...e filter when there is pressurized air in the system Starting the pump while there is any pressurized air in the system can cause the filter lid to be blown off which can cause death serious personal...

Страница 8: ...at there is no water left in the valve place the shaft back into the Slide Valve and tighten the lid union nut 7 Position the Slide Valve in Backwash mode See Section 4 Jandy DEL DEV and JS series Fil...

Страница 9: ...ash Valve Installation Operation Manual Figure 10 Slide Valve Head Loss Curve Slide Valve with DE Filter Data Shown 0 0 2 3 4 6 6 9 9 2 11 5 0 50 100 25 75 125 Flow Rate GPM Design Head Loss Feet Head...

Страница 10: ...andle 1 1 Roll Pin Shaft 13 16 1 Index Plate Lid 1 2 Rebuild Kit O rings Roll Pins and Index Plate Lid BWVL SLD R0473000 O ring Lid 1 O ring Shaft Top Black 1 O ring Shaft Bottom Purple 1 O ring Union...

Страница 11: ...Page 11 ENGLISH Jandy Pro Series Slide Valve Backwash Valve Installation Operation Manual 1 2 3 4 3 4 3 4 1 2 3 1 2 3 4 1 2 3 1 2 3 4 3 1 2...

Страница 12: ...1 800 822 7933 www ZodiacPoolSystems com ZODIAC is a registered trademark of Zodiac International S A S U used under license All trademarks referenced herein are the property of their respective owner...

Отзывы: