Page 19
Page 18
eXO
®
| Installation Manual
Section 8. Menu and Settings
8.1 Filter Pump
Both single and variable speed pumps can be
connected to and operated by the controller.
8.1.1
Single Speed Filter Pump
1. Connect the filter pump to the controller at
the pump connection point in the high voltage
raceway. For Australian installations plug the filter
pump into the socket provided on the underside
of the control unit see Table 5 and Figure 10 for
wiring details.
2. Press
.
3. Use
to select “Filter Pump”
then press .
4. Use
to select “Single Speed”
then press .
5. The user interface will prompt “Single Speed
Plugd to Device”. Use
to select “Yes”
then press .
<
-FILTER PUMP
-AUX/LIGHTS
-PROGRAMMING
-LOW MODE
-SLAVE MODE
-REVERSING
-HELP MENU
-LANGUAGE
MAIN MENU
<
-BACKWASH
-SINGLE SPEED
-VARIABLE SPEED
FILTER PUMP
<
PLUGD TO DEVICE?
-YES
-NO
SINGLE SPEED
8.1.2
Variable Speed Filter Pump
1. The following pump models are compatible:
FloPro™ VS, Flopro™ VS AUT
2. Connect the filter pump to the controller at
the VSP RS485 connection point in the low
voltage raceway, see Table 5 and Figure 10 for
wiring details.
3. Ensure the RS485 wires are in the proper order.
LOW VOLTAGE
HIGH VOLTAGE
RED
BL
K
YE
L
GRN
On the Controller
RED BL
K
YE
L
GRN
On the Pump
4. Ensure the pump DIP switches are in the
correct position as follows:
1 = up
2 = up
3 = down
4 = down
5 = up
5. Press
.
6. Use
to select “Filter Pump”
then press .
7. Use
to select “Variable Speed”
then press .
8. The user interface will prompt “Variable Speed
Plgd to Device”. Use
to select “Yes”
then press .
9. Use
to select a speed then press .
10. Use
to adjust the RPM.
11. Once desired RPM is reached, press .
12. Press
to exit.
NOTE:
If multiple VSP timers have a time slot in common
: it is the higher RPM that will be operated.
<
-FILTER PUMP
-AUX/LIGHTS
-PROGRAMMING
-LOW MODE
-SLAVE MODE
-REVERSING
-HELP MENU
-LANGUAGE
MAIN MENU
<
-BACKWASH
-SINGLE SPEED
-VARIABLE SPEED
FILTER PUMP
<
PLUGD TO DEVICE?
-YES
-NO
VARIABLE SPEED
<
VARIABLE SPEED
-SPEEDS
-MIN/MAX
-PRIMING
-PROGRAMMING
<
VSP SPEEDS
-RPM 1 1000
-RPM 2 1500
-RPM 3 2000
-RPM 4 2850
-QUICK 3450
8.1.3
Quick Clean
Quick Clean is a backwash mode is used to quickly
start/stop the filter pump (single- or variable-speed
pump) in order to backwash the filter.
For variable speed pumps, the backwash RPM is
set under “Quick”.
1. Select YES to activate filtration.
2. Select NO to stop filtration.
For safety reasons, the chlorination is stopped
during the backwash mode. To avoid emptying the
pool, the backwash mode automatically stops after
5 minutes. The variable speed pump RPM is by
default set at 3450 rpm (max speed). This can be
changed in the priming menu.