Zodiac Pool Systems JANDY TRUCLEAR XL Скачать руководство пользователя страница 20

CAUTION

 

Never use dry acid to adjust pH in arid geographic 

areas with excessive evaporation and minimal dilution 

of pool water with fresh water. A build up of by 

products can damage the electrolytic cell.

 

 

Section 6.  Operating Instructions

 

6.1 

Control PanelTurning Power Pack On/ 

Off (Manually)

 

To turn the Jandy 

TruClearXL

 chlorine generating device 

on or off press the on/off button.

 

A  quick  press  will  place  the  chlorinator  into  “standby” 
state. While in “standby” mode a quick press will return to 
“chlorinating”  mode.  If  held  down  for  6  seconds  it  will 
completely power down.

 

NOTE 

Because  the  power  pack  is  wired  to  the  pump’s 

power source, the power pack can only be turned on 
when the pump is turned on.

 

 

6.2 

Turning Power Pack On/Off (Using the 

Pump’s External Timer)

 

If  the  power  pack  is  wired  to  the  pump’s  external  timer 

and  the  power  to  the  unit  is  on,  the  power  pack  will 

automatically  turn  on  and  off  when  the  pump  turns  on 

and off (see Section 3.5). When the power pack is wired 

as such, the only setting that must be set manually is the 

chlorine output level (see Section 5.4).

 

6.3 

Chlorine Output Level

 

When setting the chlorine output level, the factors to 

consider are:

 

-

 

number of gallons in the pool

 

-

 

number of bathers (bather load)

 

-

 

amount of pollen and dust going in the water

 

-

 

number of hours the pump runs

 

-

 

whether you are using a single or variable speed pump

 

-

 

climate and water temperature

 

-

 

amount of rain water entering the pool.

 

A  good  starting  point  for  pools  at  57,000L  (15K)  gallons 
and  under  should  be  40%.  Pools  closer  to  the  95,000  L 
114,000  L  (25K  to  30K  gallons)  should  use  60%  as  a 
starting point.

 

If you find that these levels do not provide the 1 - 3 PPM 
chlorine  residual  that  is  desired,  then  raise  the  output 
level higher to compensate.

 

If you find that output level is approaching 90% to 100% 
and testing the pool water shows no or very low chlorine 
residual,  your  pool  may  need  to  be  manually  shocked 
due  to  a  waste  load  that  has  built  up  in  the  pool  water 
that  is  overwhelming  the  chlorine  you  are  supplying  to 
the pool. Another cause may be the lack of Cyanuric Acid 
(CYA)  at  appropriate  levels  to  protect  the  chlorine  from 
the UV rays of the sun.

 

NOTE 

The  unit  only  runs  while  your  pump  is  running. 

More pump runtime will result with more chlorine in 
the water.

 

With all  the  variables mentioned  above,  it  may  take  you  a 
couple weeks to find the right production rate for your pool.

 

To adjust the output level, follow these steps:

 

1.

 

Turn the power pack on by pressing the on /off
button.

 

 

2.

 

Press the up down buttons to reach the desired 
output level. The minimum setting is 10%. The 
output can be adjusted in increments of 5% up to 
100%. This controls the amount of run time for the 
cell.

 

6.4 

BOOST/LOW Mode

 

The  BOOST  mode  can  be  used  to  maximize  chlorine 
output  for  a  short  period  of  time.  To  activate  BOOST 
mode,  press  the  up  and  down  buttons  simultaneously. 
The boost will turn off after 24 hours. To turn off BOOST 
mode manually, press the left button.

 

The LOW mode can be used to minimize chlorine output

 

while activated. To activate LOW mode, press the down 
and  right  buttons  simultaneously.  The  LOW  mode  will 
stay on indefinitely. To turn off LOW mode, press the left 
button

 

6.5 

Polarity Reversal

 

The Jandy 

TruClearXL

 chlorine  generating  device  is a 

reversible  polarity  cell  which  means  that  the  cell  will 
periodically switch its  polarity  to help prevent any  build 
up  of  calcium  on  the  cell  plates.  This  is  sometimes 
referred  to  as  the  automated  cell  cleaning  feature. 
During the transition between changing its polarity there 
is  a  brief  period  when  the  cell  will  not  produce  any 
chlorine. Once it has changed polarity, it will continue to 
make chlorine.

 

The default reversal time is three hours. To change the 
reversal  time,  press  and  hold  the  up  and  down  arrows 
simultaneously to enter the service mode. Press the right 
arrow  key  once  to  select  “Cyc=”.  Use  the  up  button  to 
cycle between three and five hour cycles. Press the  left 

button to exit.

 

NOTE 

‘CLEANING’  will  be  displayed  on  the  screen 

during the ‘WAIT’ period. The output level indicator 
will remain as set during the cleaning period.

 

 

 

IMPORTANT   

Always  test  the  chlorine  levels  of  your 

pool  before  each  use.  During  heavy  usage  where 
bather  load  is  increased,  chlorine  levels  may 
deplete  quickly  and  require  more  adjustments. 
Monitor  the  chlorine  closely,  and  take  appropriate 
measures in order to maintain the recommended 1 
- 3 ppm free chlorine residual

.

 

Содержание JANDY TRUCLEAR XL

Страница 1: ...e available chlorine must be maintained AND For spas a range of 3 5 ppm of free available chlorine must be maintained READ THE LABEL AND OPERATING MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN REGISTRATION NO 33640 PEST CONTROL PRODUCT ACT WARNING operating Jandy TruClearXL without water flow through the cell can cause a buildup of flammable gases which can result in FIRE OR EXPLOSION Zodiac P...

Страница 2: ...is cell must only be used on this model of chlorine generating device READ THE LABEL THE INSTALLATION MANUAL AND OPERATION MANUAL OF THE CHLORINE GENERATING DEVICE JANDY TRUCLEARXL BEFORE USING Zodiac Pool Systems LLC 2882 Whiptail Loop East 100 Carlsbad CA 92010 USA Zodiac Pool Systems Canada Inc 2 3365 Mainway Burlington ON L7M 1A6 Canada ...

Страница 3: ...e chlorine must be maintained AND For spas a range of 3 5 ppm of free available chlorine must be maintained READ THE LABEL AND OPERATING MANUAL BEFORE USING KEEP OUT OF REACH OF CHILDREN REGISTRATION NO 33640 PEST CONTROL PRODUCT ACT WARNING operating Jandy TruClearXL without water flow through the cell can cause a buildup of flammable gases which can result in FIRE OR EXPLOSION Zodiac Pool System...

Страница 4: ... and instructions may result in property damage personal injury or death Improper installation and or operation will void the warranty Improper installation and or operation can create unwanted electrical hazard which can cause serious injury property damage or death ATTENTION INSTALLER This manual contains important information about the installation operation and safe use of this product This in...

Страница 5: ... 5 2 Determining Pool Size Gallons 5 3 Chemistry You Need to Know 5 4 Optimum Pool Water Conditions 5 5 Collecting a Water Sample 5 6 Salt NaCl Sodium Chloride When to Add Salt What Type of Salt to Use How Much Salt to Use How to Add Salt to the Pool Section 6 Operating Instructions 6 1 Turning Power Pack On Off Manually 6 2 Turning Power Pack On Off Using the Pump s External Timer 6 3 Chlorine Ou...

Страница 6: ...ice agent or electrician When installing and using this electrical equipment always follow basic safety precautions Before performing installation disconnect all power Connect to a circuit that is protected by a ground fault circuit interrupter GFCI Do not install within an outer enclosure or beneath the skirt of a hot tub or spa Do not use this device with bromide products WARNING Installation mu...

Страница 7: ...ith the pool pump motor power source to ensure that the chlorinator only operates when the pool pump is operating The flow sensor feature of the Jandy TruClearXL is intended to be used as a backup only and should not be used as the sole source of flow detection ...

Страница 8: ...rown WARNING Prolonged immersion in hot water may induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37 C 98 6 F The symptoms of hyperthermia include dizziness fainting drowsiness lethargy and an increase in the internal temperature of the body The effects of hyperthermia include Unawareness of impe...

Страница 9: ... spa water e g acids chlorine salt stabilizers etc Zodiac Pool Systems LLC does not warrant or guarantee that the chlorinated water generated by the Jandy TruClearXL chlorine generating device will not damage or destroy certain types of plants decking coping and other materials in and around your pool and or spa Before selecting materials to be used in and around your pool and or spa please discus...

Страница 10: ...chlorinator BE SURE TO COMPLY WITH THE FOLLOWING SAFETY INSTRUCTIONS Remove cell and install Pressurizing Installation and Winterizing Cap P N R0621900 before testing Check all clamps bolts lids lock rings and system accessories to ensure they are properly installed and secured before testing RELEASE ALL AIR in the system before testing AIR PRESSURE must NOT be used for pressure testing Water pres...

Страница 11: ...e place for future reference 2 1 Power Center Compatibility The Jandy TruClearXL chlorine generating cell can only function with the Jandy TruClearXL Smart Power Pack The Power Pack can be connected to any Jandy automation system using RS 485 2 2 Package Contents Before starting check that you have the correct parts as indicated below If any parts are missing or incorrect please call your local di...

Страница 12: ...ality materials and world class processes to manufacture our products Promise that your equipment will arrive completely tested in pool environments inspected and quality assured for reliability and durability We stand by our promise Our promise is backed by dedicated support and our written express product warranty For technical assistance please call 1 800 822 7933 What you say matters Tell us w...

Страница 13: ...TE If the flow direction of the water does not match the arrows on the housing the cell will malfunction 3 Let the system dry per instructions provided by the cement manufacturer 4 When the cement is dry install the cell using the unions Confirm that the flow indication arrows on the transparent lid correspond with the flow direction of the water in the plumbing system 5 Start the system and check...

Страница 14: ...t use the power pack as the common bonding point Each piece of non related pool equipment requiring a ground should also be bonded to the common approved bonding point There should be one bonding connection to the power pack In Canada the Canadian Electrical Code CEC dictates that the bonding conductor be minimum 13 3 mm2 6 AWG 4 2 Split Return Plumbing Instructions For Infloor Cleaning Systems If...

Страница 15: ...Nitrates can cause extremely high chlorine demands and will deplete chlorine from your swimming pool In some cases nitrates may even lower your chlorine levels to zero Your local pool professional can test for nitrates Make sure nitrates are not present in your pool Metals some metals can cause loss of chlorine and stain your pool Have your local pool professional check for metals and recommend me...

Страница 16: ...s TDS play a role in the calculation of the final saturation rating 5 3 1 NOTE On initial startup of a pool it is best to shock using an alternate source i e use a shock treatment available at your local pool supplier Saturation Index pH AF CF TF 12 1 A Factor AF C Factor CF T Factor TF Total Alkalinity Calci um Hardness Temperature A Factor C Factor T Factor PPM Factor Value PPM Factor Value F Fa...

Страница 17: ...least 99 8 pure NaCl The salt is an evaporated granulated food quality non iodized salt Consult your pool store Avoid using salt with anti caking agents sodium ferrocyanide also known as YPS or yellow prussiate of soda that could cause some discoloration of fittings and surface finishes in pool Water conditioning salt pellets are compressed forms of evaporated salt and may be used but will take lo...

Страница 18: ...lt as it is easier to add more if needed than it is to dilute if there is too much salt 5 Disperse salt into pool Do not add through skimmer main drain or surge tank Brush the salt around the pool to facilitate dissolving Circulate filter system for 24 hours to ensure even distribution 6 After 48 72 hours verify correct salt reading by testing the water salinity level using test strips electronic ...

Страница 19: ...2 kg 313 lbs 170 kg 376 lbs 199 kg 438 lbs 1750 47 kg 104 lbs 71 kg 156 lbs 95 kg 209 lbs 118 kg 261 lbs 142 kg 313 lbs 166 kg 365 lbs 2000 38 kg 83 lbs 57 kg 125 lbs 76 kg 167 lbs 95 kg 209 lbs 114 kg 250 lbs 132 kg 292 lbs 2250 28 kg 63 lbs 43 kg 94 lbs 57 kg 125 lbs 71 kg 156 lbs 85 kg 188 lbs 99 kg 219 lbs 2500 19 kg 42 lbs 28 kg 63 lbs 38 kg 83 lbs 47 kg 104 lbs 57 kg 125 lbs 66 kg 146 lbs 27...

Страница 20: ...vels to protect the chlorine from the UV rays of the sun NOTE The unit only runs while your pump is running More pump runtime will result with more chlorine in the water With all the variables mentioned above it may take you a couple weeks to find the right production rate for your pool To adjust the output level follow these steps 1 Turn the power pack on bypressing the on off button 2 Press the ...

Страница 21: ...needs to be cleaned See Section 6 3 for instructions NOTE Excessive cleaning can shorten the life of your cell 2 Salt Level Test Use salinity test strips a TDS salinity meter or another reliable method to test the salinity of the pool water Once the existing salinity has been established use Table 1 to determine the amount of salt to add to reach the desired level Be conservative when adding salt ...

Страница 22: ...in either of these devices until the water temperature increases Doing this will lengthen the cell life and provide better performance when water conditions are more optimal 7 A foaming action will begin which is caused by scale calcium carbonate being dissolved from the plates If foaming action does not begin the cell does not need to be cleaned STOP THE CLEANING PROCESS go to the step 10 Otherwi...

Страница 23: ...tput level Red Low Salt PIB has detected a low salt condition Off Check Salt Green High Salt Salt level is above XXXX On N A Red Short When the system is running within a valid chlorination window and detects a cell short circuit or overload conductivity problem High salt Off Check Salt and Inspect Cell Red Not Level Cell is not level 5 degrees out of alignment Off Check Cell Orientation Red Low T...

Страница 24: ...t level Red Not Authentic Off Faulty Cell Green Cell Reversing Time when cell reverses charge on plates Off Cell Reversing output level 8 2 Problems and Corrective Action Problem Possible Cause Corrective Action Low or no chlorine Low stabilizer cyanuric acid level in pool water for outdoor pools only Add stabilizer to maintain 30 50 ppm Follow your pool professional s recommendations and check al...

Страница 25: ... 3 Chlorine level too high above 7 0 PPM Chlorine output percentage set too high Decrease chlorine production rate by pressing the Output button see Section 6 3 Power pack and cell turned on too long If chlorine output is set at the lowest setting and it consistently provides excessive chlorine levels decrease operation time as much as necessary No display on LCD screen is blank No power to unit C...

Страница 26: ...ns that organic waste is being removed from the water into the air Strong odors are a part of this process If these odors persist longer than 12 hours take a water sample to your local pool dealer Manually shock the pool see Section 5 3 Cloudy water slimy walls of pool Combined algae and bacteria growth Brush down the affected walls and then manually shock the pool see Section 5 3 Eye and or skin ...

Страница 27: ...ounting bracket as a guide to mark the mounting surface 3 Drill the mounting surface and install expansion anchors as needed for the upper bracket 4 Rotate the mounting brackets 180º and install on the power center 5 Hang the power pack from the top bracket 6 Mark the mounting surface for the installation of the lower screws 7 Remove the power pack from the mounting surface 8 Drill the mounting su...

Страница 28: ...evel If the output level is 90 and tested water shows insufficient chlorine residual you may need to shock the pool or add Cyanuric Acid CYA to protect against UV degradation More pump runtime will result in more chlorine in the water It may take several adjustments over several days to find the right production rate for your application When connected to an automation system via RS485 full contro...

Отзывы: