ZMC464 Motion Controller User Manual V1.5
3.5.
OUT (Digital Output, PWM Terminal, Hardware
Comparison Output, Single-end Pulse)
The digital output adopts 2 sets of screw-type pluggable terminals with a spacing of
3.81mm, and the PWM and hardware comparison output functions are integrated in
digital output signal.
→
Terminal Definition
Terminal
Name
Type
Function 1
Function 2
Function 3
Function 4
EGND
/
External
power
ground
/
/
/
E5V
/
External 5V
power
output, max
is 300mA
/
/
/
OUT0
NPN
Leakage
type, high-
speed output
Output 0
PWM 0
Hardware
Comparison
Output
PUL4
OUT1
Output 1
PWM 1
DIR4
OUT2
Output 2
PWM 2
PUL3
OUT3
Output 3
PWM 3
DIR3
OUT4
NPN
Leakage
type, low-
speed output
Output 4
/
/
/
OUT5
Output 5
/
/
/
OUT6
Output 6
/
/
/
OUT7
Output 7
/
/
/
EGND
/
External
power
ground
/
/
/
OUT8
NPN
Leakage
type, low-
speed output
Output 8
/
/
/
OUT9
Output 9
/
/
/
OUT10
Output 10
/
/
/
OUT11
Output 11
/
/
/
Note:
The E5V power output port is used for PWM or common anode wiring of single-ended axis. It is
not recommended for other purposes due to lower power.