ZMC460 Motion Controller User Manual V1.5
IN20
Input20
/
/
IN21
Input21
/
/
IN22
Input22
/
/
IN23
Input23
/
/
Note:
IN0-3 have high-speed latch function, and IN0-11 have single-ended encoder function.
It is necessary to configure single-ended encoder axis 6-9 as local axes compulsively through
AXIS_ADDRESS. When ATYPE=0, they are general inputs.
3.4.1.
Digital Input Specification & Wiring
→
Specification
Item
High-Speed Input (IN0-11)
Low-Speed Input (IN12-23)
Input mode
NPN leakage type, the input is triggered when there is low-
electric level
Frequency
<
100kHz
<
5kHz
Impedance
3.3K
Ω
4.7K
Ω
Voltage level
DC24V
DC24V
The voltage to open
<15V
<14.5V
The voltage to close
>15.1V
>14.7V
Minimal current
-2.3mA (negative)
-1.8mA (negative)
Max current
-7.5mA (negative)
-6mA (negative)
Isolation mode
Optoelectronic isolation
Note: the above parameters are standard values when the voltage of controller power
supply (E+24V port) is 24V.