ZMC212BE Motion Controller User Manual V1.5
Terminal
PIN
Name
Type
Function
1
、
4
、
6
、
7
、
8
NC
Spare
Reserved
2
RXD
Input
RS232, receive signal
3
TXD
Output
RS232, send signal
5
GND
Output
+5V power supply output (-) and
communication public end
9
+5V
Output
+5V power supply output (+), max
is 300mA
3.2.1.
RS232 Communication Specification & Wiring
→
Specification
Item
RS232 (port 0)
Max Communication Rate
115200 (bps)
Terminal Resistor
/
Topology
Point to point (one to one)
Nodes can be extended
1
Communication Distance
Longer communication distance, lower
communication rate, max 10m is recommended.
→
Wiring Reference
→
Wiring Notes:
⚫
The wiring of RS232 is as above, the sending and receiving signals need to be cross-
connected, and it is recommended to use a double-female cross line when
connecting to a computer.