ZMC004WEA Motion Controller User Manual V1.5
Chapter III Wiring, Communication
Configuration
3.1.
Power Input, CAN Communication Interface
The power supply input adopts a 5Pin (there are all 5 terminals) screw-type pluggable
wiring terminal, and the interval (means the gap distance between two ports) should be
5.08mm. And this 5pin terminal is shared by main power and CAN communication.
→
Terminal Definition (Main Power):
Terminal
Name
Type
Function
+24V
Input
Main power 24V input
CANH
Input/output
CAN differential data +
EARTH
Earthing (Grounding)
Protect
CANL
Input/output
CAN differential data -
GND
Input
Main power / CAN public end
Note: please separately supply power for main power 24V and IO power 24V, it is not
recommended to use the same power supply, or use one power supply that can provide
2 isolated 24V outputs.
→
Terminal Definition (IO Power):
Terminal
Name
Type
Function
EGND
Input
IO Power Ground
+24V
Input
IO Power 24V input
Note: please separately supply power for main power 24V and IO power 24V, it is not
recommended to use the same power supply, or use one power supply that can provide
2 isolated 24V outputs.
Содержание ZMC004WEA
Страница 1: ......