ECI3828 Network Motion Control Card User Manual V1.5
3.4.2.
Basic Usage Method
(1)
Please follow the above wiring instructions to wiring correctly.
(2)
After powered on, please select ETHERNET, RS232 (default parameter, which can be
connected directly) and RS485 (default parameter, which can be connected directly,
for hardware, an adapter is needed) to connect to ZDevelop.
(3)
State values of relative input ports can be read directly through “IN” c
ommand, also,
it can be read through “ZDevelop/View/In”. Please refer to “ZBasic” for details.
(4)
Latch function can be set and triggered through “REGIST” instruction, in software, use
REG_INPUTS to configure. Please refer to “ZBasic” for details.
3.5.
OUT: Digital Output & PWM Terminal
The digital output adopts 2 sets of 10Pin screw-type pluggable terminals with a
spacing of 5.08mm, and the PWM function is integrated in digital output signal.
→
Wiring Definition
Terminal
Name
Type
Function 1
Function2
Function3
Function4