ECI3828 Network Motion Control Card User Manual V1.5
Chapter III Wiring, Communication
Configuration
3.1.
Power Input Interface
→
Terminal Definition:
Terminal
Name
Type
Function
E+24V
Input
Input for power supply 24V
EGND
Input
Power ground
FG
Grounding
Shield/Protection
Note:
1.
ECI3828 controller is supplied by single-power, please make sure the quality of
power supply.
2.
Controller 5V pulse axis and encoder interface use internal power supply, and IO
uses external power. Axes and encoder expanded by ZIO expansion module use
external power supply.
3.1.1.
Power Supply Specification
→
Specification
Item
Description
Voltage
DC24V (-10%~10%)
Current to open
≤0.5A
Current to work
≤0.4A
Anti-reverse connection
Valid
Overcurrent Protection
Valid
Содержание ECI3828