ECI0016PA Data Capture Card User Manual V1.5
Item
Description
Max Communication Rate (bps)
1Mbps
Terminal Resistor
120Ω
Topology
Daisy chain connection structure
The number of nodes can be
extended
Up to 16
Communication Distance
The longer communication distance is, the lower
communication rate is, max 100m is
recommended.
→
Wiring Reference
Connect the CANL and CANH of the standard CAN module to the CANL and CANH of
the other side correspondingly. And public ends of the CAN bus communication both
parties are connected together. In CAN bus left and right sides, connect a 120
Ω
resistor
respectively (please see below graphic).
→
Wiring Notes:
⚫
As above, the daisy chain topology is used for wiring (the star topology structure
cannot be used). When the use environment is ideal and there are no many nodes,
the branch structure also can be used.
⚫
Please connect a 120Ω terminal resistor in parallel
to each end of the CAN bus for