7.2  Configuration Parameters 

Table 7.10 Configuration parameter description 

Category 

Property Name 

Default 

Parameter Description 

Basic information 

Device model 

CANFDNET-20

0U 

This item cannot be changed. 

Firmware version 

Current firmware version of the device, such as 1.00.00. 

Hardware version 

Current hardware version of the device, such as 1.00.00. 

Equipment No. 

Device serial number. Each device has a different device serial 
number. It is a 16-byte string. 

Equipment name 

CANFDNET-20

0U 

Device name. The value can be changed, a maximum of 15 
characters. ASCII characters can be used. Modifying this value is 
very useful for users to identify multiple devices on the same 
network. 

Password operation 

Current password 

88888 

Before changing other items, you must enter the correct 
password. Use ASCII characters as the password. The password 
can contain a maximum of 9 characters. 

Whether to 
change the 

password 

No 

Only when you select "Yes", you can enter "New Password" and 
"Confirm Password". 

New password 

If "Whether to change the password" is "No", the password 
cannot be changed. Used to enter a new password. The 
maximum length of the password is 9 characters. For the 
character range, see "Current Password" . 

Confirm the new 

password 

If "Whether to change the password" is "No", the password 
cannot be changed; 
Used to confirm the new password. The content must be 
consistent with the "new password". 

Network Settings 

DNS1 

192.168.0.1 

Preferred DNS server address. 

DNS2 

192.168.1.1 

Alternative DNS server address. 

For all 

Ethernet/Vehicle 

Ethernet 

MAC address 

The MAC address is different for different devices. It can be 
changed. The default MAC address can be restored. 

DHCP enable 

No 

After being enabled, the device will obtain information such as the 
IP address, subnet mask, and gateway from the network. If it is 
disabled, the user sets the IP address, subnet mask, and 
gateway. Note: After confirming that there is a DHCP server on 
the network, DHCP can be enabled. Normally, the router also has 
the DHCP server function. 

IP 

192.168.0.178 

(Universal 

Ethernet)/ 

192.168.1.178 

(vehicle 

Ethernet) 

Do not enter X.X.X.0 or X.X.X.255. An IP address is an address 
on a network assigned to a network device, and it is unique on 
the same network. 

Subnet mask 

255.255.255.0 

The subnet mask is very important for the network. In the same 
network, each IP address 
and the subnet mask are equal to the obtained value. So, set 
them correctly 
"IP address" and "subnet mask". 

Gateway 

192.168.0.178 

(Universal 

Ethernet)/ 

192.168.1.178 

(vehicle 

Ethernet) 

Enter the IP addresses of the gateway or router in this network. 

Содержание CANFDNET-200U

Страница 1: ...CAN FD BUS forwarding Ethernet Abstract Product User Guide 2021 Guangzhou ZLG Electronics Co Ltd High Performance Dual Channel Ethernet to CAN FD Converter CANFDNET 200U User Manual UM01010101 1 0 00...

Страница 2: ...NFDNET 200U High Performance Dual Channel Ethernet to CAN FD Converter User Manual 2021 Guangzhou ZLG Electronics Co Ltd 2 User Manual Revision History Version Date Description V1 00 2019 12 28 Create...

Страница 3: ...icators 5 4 3 Buttons 6 4 4 Power Interface 6 4 5 CAN bus Interface 6 4 6 Ethernet Interface 8 4 7 Vehicle Ethernet Interface 9 5 Quick Instructions 10 5 1 Hardware Connection 10 5 2 Software Installa...

Страница 4: ...thernet interface and provides a stable TCP IP protocol stack It helps users easily interconnect the CAN FD bus network and Ethernet and further expands the scope of CAN FD bus network CANFDNET 200U i...

Страница 5: ...nd large capacity buffering Multiple work modes supported Work modes TCP Server TCP Client UDP Supports a maximum of two TCP servers each of each supports a maximum of 16 connections or supports a max...

Страница 6: ...age kV Test Result Remarks Power supply Level 4 6 Class A Contact discharge CAN bus Level 4 6 Class A Contact discharge Ethernet Level 4 6 Class A Contact discharge Buttons Indicators Level 4 8 Class...

Страница 7: ...nce Dual Channel Ethernet to CAN FD Converter User Manual 2021 Guangzhou ZLG Electronics Co Ltd 4 User Manual 3 Mechanical Dimensions The mechanical dimensions are shown in the following figure unit m...

Страница 8: ...shows the device panel layout Figure 4 1 Panel layout 4 2 Indicators Table 4 1 LED indicators Identification Function Status Description PWR Power indicator Red The device is powered on properly Light...

Страница 9: ...er pressing the button release it within 2 seconds to reset the device if you press and hold 5 seconds the button until the system indicator SYS turns red the device restores its factory settings auto...

Страница 10: ...receiving differential positive phase signal 7 CAN_FG Shielding ground 5 NC Not connected 1 4 8 9 Table 4 7 CAN Bus interface specifications Item Minimum Typical Value Maximum Unit Communication baud...

Страница 11: ...ion distance and communication rate are related to the field application and can be designed according to the actual application and related standards The CAN Bus cable can be ordinary twisted pair sh...

Страница 12: ...l which realizes vehicle Ethernet communication This interface meets the 10 100M specification Table 4 9 Table 4 10 and Figure 4 3 show the interface diagram and signal definition Table 4 9 Vehicle Et...

Страница 13: ...connect the LAN port of the device to the network port of the PC 5 2 Software Installation Before using the device install the ZCANPRO V2 0 39 or above which can be downloaded from the official websit...

Страница 14: ...2 to search for devices in the network After the device is searched the interface is displayed as shown in Figure 5 3 Click the red circle in the figure and select the device to obtain information Af...

Страница 15: ...set with a default IP address 192 168 0 178 and network mask 255 255 255 0 when it leaves the factory Check whether the device is in the same network segment as the user s PC according to the process...

Страница 16: ...r example if the IP address of the PC is 192 168 7 115 the subnet mask is 255 255 255 0 and the default gateway is 192 168 0 1 change IP of General Ethernet to 192 168 7 178 and change the device gate...

Страница 17: ...TCP Server Mode In TCP Server mode the device will not actively connect with other devices It always waits for the connection of the client TCP Client and can carry out two way data communication afte...

Страница 18: ...e with the device To verify whether the device communication is normal connect CAN0 and CAN1 of the device the baud rate must be the same to carry out the message sending and receiving test Click the...

Страница 19: ...onnection conditions After establishing a TCP connection with the TCP server two way data communication can be carried out When the device acts as a TCP Client the PC should act as a TCP server Open t...

Страница 20: ...oo much additional communication volume and can provide a higher communication speed than the TCP method to ensure the real time transmission of data packets In fact when the network environment is si...

Страница 21: ...Ethernet to CAN FD Converter User Manual 2021 Guangzhou ZLG Electronics Co Ltd 18 User Manual Figure 5 11 Starting CANFDNET UDP Click OK The device can communicate with ZCANPRO For message sending an...

Страница 22: ...n the network configuration tool 6 2 Restoring Factory Settings There are two ways to restore factory settings key and software After pressing the button for 5 seconds release the button to restore fa...

Страница 23: ...cs Co Ltd 20 User Manual Software upgrade firmware After searching for the device right click the device and choose Upgrade on the pop up interface as shown in the red box in Figure 6 1 Load the upgra...

Страница 24: ...he device uploads a message the maximum number of messages is set and the network sends a maximum of 50 CAN messages each time The type parameter is 0 reserved The data length is n x the length of the...

Страница 25: ...nel 1 CAN FD channel starting from 0 the value of CANFDNET 200 is 0 1 When sending a message if the channel number is 1 the message is sent to all CAN channels Data length 1 Length of the message data...

Страница 26: ...on No 1 Timed sending number The value is 0 31 Enable 1 Timed sending enable 1 enable 0 disable Period 2 Sending cycle in ms The value is 1 60 000 ms Times 2 Sending times The value ranges from 0 to 6...

Страница 27: ...length of the password is 9 characters For the character range see Current Password Confirm the new password If Whether to change the password is No the password cannot be changed Used to confirm the...

Страница 28: ...ing Message filtering settings Click the attribute value in this column The filter setting interface appears For description of setting items see Table 7 11 Timing sending Timed sending settings Click...

Страница 29: ...erty Name Default Parameter Description Enable Disable Selecting means enabling ID 0 Message ID expressed in hexadecimal notation Sending cycle 1000 Timed sending period in ms Number of Sending 0 The...

Страница 30: ...rames reaches the number of packet frames the received data is encapsulated into an Ethernet packet and sent to the network port The number of packet frames refers to the maximum number of frames in t...

Страница 31: ...optional work modes are as follows TCP server TCP client UDP Local port Local working port The value ranges from 0 to 65535 When it is 0 the system randomly allocates ports When the work mode is TCP S...

Страница 32: ...will try to present detailed and accurate product information to users in this manual However due to the effectiveness of this manual within a particular period of time ZLG Electronics does not guara...

Страница 33: ...D Converter User Manual 2021 Guangzhou ZLG Electronics Co Ltd 30 User Manual Dreams come true with professionalism and dedication Guangzhou ZLG Electronics Co Ltd For more details please visit www zlg...

Отзывы: