background image

ZK-MD6000 Series

                                

User Manual and Installation Guide 

 

P a g e

 | 13 

Copyright © 2022 ZKTECO CO., LTD. All rights reserved. 

6

 

Installation 

Please follow the installation steps below after reading the installation 
precautions and checking the packing list: 

Step 1

: Unpack the package, and place the left and right door panels on 

the ground, with the power boards of the two door panels facing outward, 
as shown in the figure below. 

 

Step 2

: Insert the wires inside the machine head into the corresponding 

positions. 
Left door panel internal interface identification: 

 

 
 
 
 

Содержание ZK-MD6000 Series

Страница 1: ...arefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For further details please vis...

Страница 2: ...s in and is the property of ZKTeco The contents hereof should not be used or shared by the receiver with any third party without express written permission of ZKTeco The contents of this manual must b...

Страница 3: ...information is assumed by the user ZKTeco in no event shall be liable to the user or any third party for any incidental consequential indirect special or exemplary damages including without limitatio...

Страница 4: ...ration of the machine and equipment in conditions different from the prescribed conditions of the manual The product will be updated from time to time without prior notice The latest operation procedu...

Страница 5: ...arch and development of biometric verification procedures and the productization of biometric verification SDK which was initially widely applied in PC security and identity authentication fields With...

Страница 6: ...onvention Description Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi le...

Страница 7: ...reserved Table of Contents 1 NOTE 7 2 PRODUCT SPECIFICATION 8 3 INSTALLATION ENVIRONMENT 10 4 PERFORMANCE AND FEATURES 11 5 PARTS 12 6 INSTALLATION 13 7 DETECTION ZONES 17 8 OPERATION 18 SYSTEM MENU B...

Страница 8: ...where the reflection or light is not strong enough to affect face recognition 4 Choose a stable installation location to avoid false alarms caused by excessive shaking of the product 5 Make sure that...

Страница 9: ...as it may cause false alarms 12 This is not a medical device and the data cannot be used for medical purposes It is just used to check your body temperature 2 Product Specification ZK MD6000 series W...

Страница 10: ...crowd rush walk slowly or crush the door panel 4 Before passing through the metal detector the pedestrians must remove all the carried metal objects such as keys mobile phone watch coins etc and plac...

Страница 11: ...and fixed to avoid false alarm after installation by the movement of people walking or moving and shaking of metal objects 4 Electromagnetic Radiation and Electromagnetic Interference As the device us...

Страница 12: ...rding to the actual environment and the operating frequency selected by the walk through metal detector 4 Performance and Features Enhanced Detection 33 detection zones and 500 sensitivity levels Ther...

Страница 13: ...nual and Installation Guide P a g e 12 Copyright 2022 ZKTECO CO LTD All rights reserved 5 Parts 1 Door Panel 2 Main Box 3 Access Control Device 4 Entrance Control Device 5 Cameras and Thermal Imaging...

Страница 14: ...ter reading the installation precautions and checking the packing list Step 1 Unpack the package and place the left and right door panels on the ground with the power boards of the two door panels fac...

Страница 15: ...ctor on the rear of the turnstile and insert the wires protruding from the lower part of the walk through metal detector into the left and right chassis from the back of the turnstile Step 5 Connect t...

Страница 16: ...n the three screws on the side connect the U shaped interface cables in the order of brown blue and yellow green from left to right and then tighten the screws Step 8 Push the walk through metal detec...

Страница 17: ...All rights reserved On Off 1 Before plugging in the power check whether the cables are properly connected and not loose 2 Connect the power plug of the console to 220V commercial power 3 Press the on...

Страница 18: ...e zone indicators can be turned on or off If the metal detector detects metals of the size that reach or exceed the preset value the alarm indicator of the detection zone turns on and an alarm is gene...

Страница 19: ...ideo duration face capture and display of binding measurement of human body temperature thermal imaging preview screen face capture and display of temperature measurement and high temperature alarm Wa...

Страница 20: ...isplay the card number photo and name etc System Menu Bar 8 1 Click the menu bar to display the buttons for login registration password modification and user logout Login Enter the super administrator...

Страница 21: ...Video Face Thermal Blocklist Identity System and About 1 WTMD You can set the alarm duration volume system channel overall sensitivity alarm mode system defense zone sensitivity of each area all sensi...

Страница 22: ...ZK MD6000 Series User Manual and Installation Guide P a g e 21 Copyright 2022 ZKTECO CO LTD All rights reserved 2 Video Display the saved surveillance videos only load 30 at a time...

Страница 23: ...Installation Guide P a g e 22 Copyright 2022 ZKTECO CO LTD All rights reserved Click the monitoring video after the loading is completed the first frame of the video will be displayed and then click...

Страница 24: ...All rights reserved 3 Face Displays the measured temperature photos taken and time taken 4 Thermal Imaging Display all photos whose temperature is higher than the temperature set by the system and th...

Страница 25: ...ueried 7 System Set the alarm temperature manual calibration temperature calibration value of the horizontal and vertical directions of the visible light and thermal imaging fusion and the alarm value...

Страница 26: ...ZK MD6000 Series User Manual and Installation Guide P a g e 25 Copyright 2022 ZKTECO CO LTD All rights reserved...

Страница 27: ...Android RAM 2GB ROM 2TB Monitor 29 inches Operating Temperature 10 C to 35 C Operating Environment Indoor Input Voltage 100V to 240V 50 60Hz WTMD Zones 33 Zones WTMD Working Frequency 5 7kHz to 9 6kH...

Страница 28: ...l MCBF 2 Millions Certifications ISO9001 ISO 14001 CE FCC Arm Type One Drop Arm Arm Length 620mm Transparent Acrylic Board L W H 620mm 10mm 1098mm 2 PCS Detectable Gas CO CH2O H2 NH3 etc Capacity 30 0...

Страница 29: ...6mm 2460mm 1730mm 1046mm 2460mm Entrance Control Dimension L W H 1730mm 1046mm 1350mm Dimensions with Packing L W H Package1 2550 720 458mm Door Panel Package 2 860 580 486mm Control Unit Package1 255...

Страница 30: ...ranty Card 1 Please keep this card with reasonableness and show it when maintaining it 2 This card will be invalid if without the signature or stamp of the designated dealer 3 This card will be regard...

Страница 31: ...Manual and Installation Guide P a g e 30 Copyright 2022 ZKTECO CO LTD All rights reserved Model Number ID Date Acquisition User Post Code Address User s Phone Number Fax Date of Maintenance Record of...

Страница 32: ...2022 ZKTECO CO LTD All rights reserved ZKTeco Industrial Park No 32 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2022 ZKTECO CO LTD A...

Отзывы: