ZK-D4330 (TP Version) User Manual
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
P a g e
|
33
Operation:
Press the
[OK]
button to enter the alarm mode setting interface, then press the
[▲]
/
[▼]
button to select, press
[OK]
button to save and exit.
Random alarm
Select
Random alarm
on the Alarm setting interface, and press
OK
to enter the random alarm
setting interface, as shown in the following:
Under normal circumstances, the alarm is generated when the amount of metal signal reaches
the set sensitivity threshold, while it can pass normally when it is less than the threshold. When
a random alarm value is set, there will be a n% probability that a normal pass without alarm will
be turned into an alarm, so that it can be checked and confirmed again manually.
Operation:
Press the
[OK]
button to enter the random alarm setting interface, then press the
[▲]
/
[▼]
button to set the value, press
[OK]
button to save and exit to the upper menu after finishing, directly
press
[
⏎
]
button to exit to the upper menu without saving the current value.
8.7
Auto Testing
Select
Auto Testing
on the
Main Menu
interface, and press
OK
to enter this option where the
system self-checks its functions. As shown in the following: