background image

 

 

 

 

Содержание VT07-C22L

Страница 1: ...User Manual USER MANUAL VT07 C22L For TCP IP with 2WIRE system April 2023...

Страница 2: ......

Страница 3: ...only for reference If there is any difference please take the actual product as the standard The product and batteries must be handled separately from household waste When the product reaches the end...

Страница 4: ...al Parameters 1 Pictures 2 Operations 7 1 Security 8 2 Smart 14 3 Intercom 17 4 Message 20 5 Setup 20 Web Settings 23 System Configuration 25 System Diagram 29 Installation 31 Troubleshooting 34 Safet...

Страница 5: ...sion by RS485 communication Optional 2 Operating system Linux Technical Parameters Voltage DC 48V Rated power 7W VT07 C22L VT07 C23L 8W VT10 B21L Standby power consumption 3W Display screen 7 10 1 Tou...

Страница 6: ...Pictures Model VT10 B21L Speaker 10 1 capacitive touch screen Microphone Model VT07 C23L 7 capacitive touch screen Speaker Handsfree Reserved Calling management center Monitoring Unlocking Microphone...

Страница 7: ...Model VT07 C22L With keys 7 capacitive touch screen Microphone Speaker Unlocking Monitoring Calling management center Reserved Handsfree...

Страница 8: ...one Indoor monitor doesn t support the connection with external camera audio extension WIFI Bluetooth external USB and TF storage card Standard indoor monitor doesn t include RS485 communication funct...

Страница 9: ...to check and call contacts 3 SOS Click to make a direct emergency call to Master Station 4 Lift control Click to summon the elevator to go up or down Click Permit inside of it to release the floor bu...

Страница 10: ...ystem will enter into the following interface When the call is answered the system will enter into call state 1 If there is a camera the caller s image will be displayed on the screen 2 When the call...

Страница 11: ...oor station or secondary door station calls the indoor monitor will ring when door station calls indoor monitor the image from door station will be displayed on the indoor monitor if there is no answe...

Страница 12: ...he type of door station Click icon Click to start monitoring 2 Click icon Click icon to select the type of door stationClick to start monitoring During monitoring click icon to unlock the door Remark...

Страница 13: ...installed on the computer which is usually located at guard center Up to 64 records can be received in SMS 4 Security Click Security icon on the main interface the system will enter the following inte...

Страница 14: ...user password the default password is 1234 to disable the alarm under alarm ON status 4 2 Zone Remark the settings should be made when alarm is OFF Click Zone icon and input 1 16 digits password the d...

Страница 15: ...setting it will show the following interface with selections 0s 5s 15s 20s 25s 40s or 60s as the desired delay time For example select the delay time 5s Once the alarm sensor is triggered the indoor m...

Страница 16: ...to Alarm OFF To set the sensor of alarm stations you can click the corresponding station with icon Click Activation Time to select the corresponding time The options of activation time include NONE 3...

Страница 17: ...in interface the system will enter the following interface Click icon to call master station the system will call master station No 1 No 5 successively If the master station cannot be searched or call...

Страница 18: ...lease follow the operations as below 1 Click icon to select the camera Click icon Click to start monitoring 2 Click icon Click icon to select the camera Click to start monitoring Remark The system s d...

Страница 19: ...er Ring Vol Intercom Vol and Ringtone can be set 7 3 Date Time Click Date Time icon the system will enter into the following interface This interface can set Auto Date Time Zone 12H 24H Date Format an...

Страница 20: ...e can be switched 7 5 Devices Click Devices icon the system will enter into the following interface The device information can be viewed 7 6 Version Click Version icon the system will enter into the f...

Страница 21: ...digits password the default password is 123456 to make the following settings 7 7 1 Network Click Network icon the system will enter into the following interface After using the DHCP the router will a...

Страница 22: ...the address can be ignored 7 7 2 Room Click Room icon the system will enter into the following interface Warning Please revise Sync No 6 digits as soon as possible after you read the user manual The S...

Страница 23: ...e following interface You can set the new system password with 1 16 digits the default password is 123456 System password is used for system settings 7 7 4 Reset Click Reset icon the system will enter...

Страница 24: ...d is 123456 to enter into the web setting interface Main page is used for showing firmware version and the status of SIP registration 1 Network Network page is used for setting up network of device he...

Страница 25: ...or Station 1 9 Sync type in same numbers to make same room number Indoor Monitors ring together Server Password server is the IP of CMS and password is the admin s password of device 3 VOIP VOIP page...

Страница 26: ...outbound server leave it blank User Password account and password of SIP...

Страница 27: ...ported Auto Pickup pick up automatically when receiving a call ONU Pass if using optical cable but not network cable in the building it should be enabled Deaf Mode enable this when Indoor Monitor conn...

Страница 28: ...thers Others page is used for reboot Reboot click to reboot the device 6 Logout Logout page is used for signing off User Logout click to logout the webpage After that you can use other accounts to log...

Страница 29: ...0 5 Exit Button Wall Panel 220V CAT 5e CAT 5e Fiber Optical Transceiver Camera Electric Outdoor Fiber Optical Transceiver Network Switch RVV2 0 5 IP 2WIRE Camera RVV2 0 5 48V 48V Fiber Optical Transc...

Страница 30: ...System Configuration System Configuration...

Страница 31: ......

Страница 32: ......

Страница 33: ...S0 S3 S6 S8 S9 1 Power Power input interface nonpolar input power over 2 wire cable 2Wire 2 RS485 Connect with smart home and alarm external module etc Offer a group of 12V 100mA power by RS485 12V 1...

Страница 34: ...erface of 8 alarm zone with 3 states can be connected with normally open or normally closed switch Offer a group of 12V 100mA power by alarm interface 2 2K Normally open sensor Alarm Normally closed s...

Страница 35: ...System Configuration Installation Model VT10 B21L Built in box Screws Size 270 168 15mm Model VT07 C23L Built in box Screws Size 235 145 19 5mm...

Страница 36: ...5mm Installation Instructions 400 500mm Suggestion During the installation the camera should be 1450 1550mm above the ground The camera tether for photographing human face should be the top priorit S...

Страница 37: ...annot be played normally Check whether the system supports the file format Please refer to multimedia setting for details No response when clicking indoor monitor display screen Press Unlock button fo...

Страница 38: ...r cause the impact Do not use the power supply without the manufacturer s approval Do not have the liquids such as water go into the device Clean Device Surface Clean the device surfaces with soft clo...

Страница 39: ......

Отзывы: