Normal Open Time
Period
Scheduled time period for “Normal Open” mode, so that the door is always unlocked
during this period.
Master Device
When setting up the master and slave devices, the status of the master device can be
set as out or in.
Out:
The record verified on the host is the exit record.
In:
The record verified on the host is the entry record.
Auxiliary Input
Configuration
Set the door unlock time period and auxiliary output type of the auxiliary terminal
device. Auxiliary output types include None, Trigger door open, Trigger Alarm,
Trigger door open and Alarm.
Speaker Alarm
To transmit a sound alarm or disassembly alarm from the local. When the door is
closed or the verification is successful, the system will cancel the alarm from the local.
Reset Access
Setting
The restored access control parameters include door lock delay, door sensor delay,
door sensor type, verification mode, door available time period, normal open time
period, master device, and alarm. However, it does not include the deleted access
control data in Data Management.
10.2
Time Schedule
The entire system can define up to 50 time periods. Each time period represents seven time zones, i.e. one week,
and each time zone is a valid time period within 24 hours per day. User can only verify within the valid time
period. Each time zone format of the time period: HH MM-HH MM, which is accurate to minutes according to
the 24-hour clock.
Click
Time Schedule
on the Access Control interface.
1. Click the grey box to input a time zone to search. Enter the number of time zone (maximum: 50 zones).