ProBio & ProFAC User Manual
35
10 Access Control
Access Control option is used to set the Time Rule, Holidays, Combined Verification etc., the related
parameters for the device to control the lock and other devices.
To gain access, the registered user must meet the following conditions:
1.
User’s access time falls within either user’s personal time zone or group time zone.
2.
User’s group must be in the access combo (when there are other groups in the same access combo,
verification of members of those groups are also required to unlock the door).
In default settings, new users are allocated into the first access group with the default group time rule [1]
and access combo as “1”, and set in unlocking state.
10.1 Access Control Settings
In the initial interface, press
>
Access Control
>
Access Control Options
to enter the
Access
Control Options
setting interface.
Door Lock Delay (s):
The time period for unlocking the door (from door opening to closing
automatically) after the electronic lock receives an open signal from the device (value ranges from 1 to
10 seconds).
Door Sensor Delay (s):
When the door is opened, the door sensor will be checked after a time period; if
the state of the door sensor is inconsistent with that of the door sensor mode, alarm will be triggered.