EFace10
User Manual
P a g e
| 44
Copyright©2021 ZKTECO CO., LTD. All rights reserved.
9
Access Control
On the
Main Menu
, tap
Access Control
to set the schedule of lock.
Access Control Options
9.1
Tap
Access Control Options
on the
Access Control
interface to set the parameters of the control lock of
the terminal and related equipment.
Function Description
Function Name
Description
Door Lock Delay (s)
The amount of time that the device controls the electric lock to be in unlock
state.
Valid value: 1~10 seconds; 0 seconds represents disabling the function.
Door Sensor Delay
(s)
An alarm is triggered if the door is not closed within a defined time (Door Sensor
Delay).
The valid value of Door Sensor Delay ranges from 1 to 255 seconds.
Door Sensor Type
There are three Sensor types:
None, Normal Open,
and
Normal Closed
.
None:
It means the door sensor is not in use.
Normal Open:
The door is always open when electric power is on.
Normal Closed:
The door is always close when electric power is on.