BG1000 Series Barrier Gate
User Manual
P a g e
| 20
Copyright©2020 ZKTECO CO., LTD. All rights reserved.
The display status is given below:
Parameter Settings Description
8.2
Parameter
Description
Menu List
3m
Boom
4.5m
Boom
6m
Boom
Gate Opening Speed
Adjustment
The larger the value, the
faster the opening speed
L-1
90
70
60
Gate Closing Speed
Adjustment
The larger the value, the
faster the gate closing
speed
L-2
85
65
55
Barrier Boom balance
Adjustment
Default
L-3
12
12
12
Anti-smashing Car
Response Time
Sensitivity Adjustment
The shorter the
reaction time, the
higher the sensitivity.
L-4
30
30
30
Motor Strength
Adjustment
Default
L-5
70
70
70
Horizontal Boom
Barrier Adjustment
-
L-6
5
5
8
Test Mode Selection
0 – Manual
1 - Automatic (default)
L-7
0
0
0
Turn on Memory
function
0 – No Memory
1 - Memory
4 - Peak mode(default)
L-8
0
0
0
Vertical Boom Barrier
Adjustment
-
L-9
5
5
8
Deceleration stroke
adjustment of the first
stage of opening
brake
-
L-L
45
65
40
Deceleration stroke
adjustment of the
second stage of
closing brake
-
L-B
55
55
40
Anti-Smashing Vehicle
Strength Adjustment
The larger the value,
the more severe the
damage to the object.
L-C
50
50
50
Forward and Reverse
operation setting of
the barrier
Type 1 - L
Type 2 – R
(Factory setting)
L-D
1 or 2
1 or 2
1 or 2
Motor force when the
barrier is activated
Torque output by the
motor when the
L-E
30
30
30