Страница 1: ...User Manual Version 1 1 Date December 2011 ...

Страница 2: ... 6 2 6 2 Tamper Switch 6 2 7 Cleaning Terminal 6 2 8 Restarting Restting the unit 7 2 8 1 Restarting Terminal 7 2 8 2 Resetting Terminal 7 3 Connections 7 3 1 USB Port 7 3 2 TCP IP 7 3 2 1 Using TCP IP 7 3 3 RS232 RS485 Wiegand port 8 3 3 1 Using RS232 8 3 3 2 Using RS485 8 3 4 Power Supply Port 8 3 5 Access Control Port 8 3 6 Using USB 8 3 6 1 Using USB 8 3 7 Communication Key 8 4 User 9 4 1 Enro...

Страница 3: ...uto Alarm 11 5 1 7 Defining Work Codes 11 5 3 System Information 12 5 3 1 Number of Users in the Terminal 12 5 3 2 Quantity of Attendance Logs Saved 12 5 3 3 Number of Admins Registered 12 5 3 4 Number of Password User Available 12 5 3 5 Number of Time Scanners Used 12 5 3 6 Free Space 12 5 3 7 Device Information 12 5 4 Log Information 13 5 4 1 Alarm Super Log 13 5 4 2 Alarm Attendance Log 13 5 4 ...

Страница 4: ...ion 17 8 5 Lock 17 8 6 Door Sensor Delay 17 8 7 Door Sensor Mode 17 8 8 Door Sensor Alarm 17 8 9 Turning Off Alarm 18 8 10 Alarm Count 18 8 11 Group Verification Type 18 9 RFID card function 18 9 1 Understanding the RFID Card 18 9 2 Enrolment of RFID Card 18 9 3 Verification using RFID Card only 18 9 4 Multi verification Methods 18 9 5 Deleting RFID Card 19 10 Autotest 19 10 1 Who Should do the Au...

Страница 5: ...1 Troubleshooting 20 11 1 Unable to connect Appears 20 11 2 Admin affirm Appears 20 11 3 LED is Blinking all the Time 20 11 4 RFID Card doesn t Respond 20 11 5 No Sound 20 Table of contents continue 3 2 ...

Страница 6: ...to the outdoors for long periods of time it is recommended to adopt sunshade and heat dissipation facili ties because excessively high or low temperature may slow down the device operation and result in high false rejection rate FRR When installing the device please connect the power cable after connecting other cables If the device does not operate properly be sure to shut down the power supply b...

Страница 7: ...late on the wall securely and attach the terminal to the back plate when mounting it on the wall 2 2 Product Appearance Front view LCD Screen Displaying status of terminal day date and time LED Display Green LED The terminal is working fine and it is in standby mode Red LED There is an error at the terminal that requires checking For first time use the terminals need to be charged fully to avoid h...

Страница 8: ...ith locks and power supply through cables Tamper Switch Used to generate a tamper alarm 2 3 Keypad You can insert inputs into the terminals through the keypad It contains numbers from 0 9 an OK button an ESC Cancel button a Scroll up down button a doorbell button and a Menu button Keypad used for user password pin entry and navigation of the unit USB port is situated on the side of unit 5 Reset Bu...

Страница 9: ...stem Option Adv Option Adj VOL adjust accord ingly 2 6 Security Features Security features help protect the information in the terminal from being accessed by unauthorized individuals 2 6 1 Admin Affirm Register an administrator into the system by enrolling a card or password to a user ID Press Menu User Manage Enroll Admin Choose enrollment method Perform enrolment and Save After enrolling an adm...

Страница 10: ...res Ethernet 10 100Base T Crossover Cable The cable can be used to cascade hubs or to connect Ethernet stations back to back without a hub It works with both 10Base T and 100Base TX 3 2 1 Using TCP IP Determining the IP Address IP address is important as it is a unique address of the terminal in LAN Without the IP ad dress locating the specific terminal is not possible To input the IP address of t...

Страница 11: ...etween the terminal and the software but the speed must be according to the speed of the converter Check your converter for the speed To turn on RS485 connection and set the baud rate Press Menu Options Comm Opt RS232 Change the RS485 connection to Y To change baud rate Press Menu Options Comm Opt Baud rate Change the Baud rate accord ingly 3 4 Power Supply Port Insert the Power Adapter point to t...

Страница 12: ... Password Enrolment The terminals offer password verification and the maximum length of password is 5 digit Enrolling password Press Menu User Manage Enroll User Enroll Pwd New Enroll OK Key in User ID PIN OK Input your password LCD showing the ID with minus P to indicate that the user ID is using password OK Save Changing password Press Menu User Manage Enroll User Enroll Pwd ESC Input User ID OK...

Страница 13: ... of Verification Methods The terminals offer various verification methods which include Password PW and RFID RF You can configure the terminal to offer multi verification methods Press Menu Options Access Options Group VerType Select the Group OK Select the time OK Down arrow and select Verification Type OK The terminals support the following combinations of verification VERIFICATION TYPE DESCRIPT...

Страница 14: ...go as high as 100 and as low as 0 To sustain the performance of speaker in the terminal it s recom mended to stay at range 60 70 To adjust the volume Press Menu Options System Opt Adv Option Adj VOL Set your number OK 5 1 5 User Interface Style The terminals offer different user interface style Select your style based on your prefer ence Press Menu Options UI Style Select your style OK 5 1 7 Auto ...

Страница 15: ...r 5 3 4 Number of Password Users Available in the Terminal Password User Users can do verification using PIN password and a combination of card and password To find out how many users are using password Press Menu Sys Info Password User View the number 5 3 5 Number of Time Scanners Have Been Used for Verification S Logs S logs stands for scanner logs which means the number of times the scanner has...

Страница 16: ...the terminal requires the correct MAC address Without availability of MAC address the software will not be activated correctly All products are supplied with the cor rect MAC address to ease communication This is also to hinder people from using the software with a different hardware brand An example of a MAC address is 00 0A 5D F1 BE 57 Press Menu Sys Info Dev Info View MAC MCU Version An MCU is ...

Страница 17: ...r Admin Privilege operation allows the current administrator to clear all his her data to make way for the new administra tor s data Once the operation is completed system menu is accessible by all users Press Menu Options System Opt Adv Option Clr Admin Pri OK Continue OK 6 1 4 Resetting to Factory Settings Reset Option This feature is to restore all settings in the terminal to return to the orig...

Страница 18: ...mation from the software to the terminal by using a USB Flash Disk Press Menu PenDrive Mng UpLoad User The terminal would require you to plug in the USB Flash Disk to proceed 7 6 Uploading Short Messages Some the terminals can display a short messaging system on the LCD The SMS can be private or public To assign sms to an individual or all staff using USB Press Menu PenDrive Mng Upload SMS Insert ...

Страница 19: ...ring weekends Therefore these users will be in Group Time Zone 1 The table below illustrates the Group Time Zone concept GROUP TIME ZONE TIME ZONE TIME ZONE TIME ZONE 1 2 3 There are a total of 5 Group Time Zones available in the system The system default is Group 1 and Time Zone 1 Therefore the newly enrolled users automatically will be in an unlocking status If those users are not included in th...

Страница 20: ...o alert users if a door is not closing well after a time period A door sensor must be installed prior to activation of this option The default period is 10seconds and the maximum period is 999seconds Press Menu Options Access Options Dsen Delay Determine the value of lock delay 8 7 Door Sensor Mode Door sensor mode is to configure the time to alert an internal buzzer if the door is not closing pro...

Страница 21: ...fication or better known as RFID system The terminals accept RFID card with specifications of 64 bit 125kHz 9 2 Enrolment of RFID Card RFID can be enrolled alone with or without password Each RFID card comes with a unique ID and the terminals will read from the numbers and match it with the card Enrollment of RFID is easy Press Menu User Manage Enroll User Admin Reg RFID OK Do you want to do new e...

Страница 22: ...layed The terminal will run all tests and when finished the LCD will dis play the result such as this All 31 Bad 0 to indicate the level of breakdown in the terminal 10 3 FLASH Test Press Menu Options Auto Test FLASH test OK Pls keep Pwr On message will be displayed The terminal will run all tests and when finished the LCD will dis play the result such as this All 31 Bad 0 10 4 LCD Test Press Menu...

Страница 23: ...blem in the termi nal Charge your terminals for a few hours to avoid the red light from blinking Consult your reseller for technical advice 11 4 RFID Card Doesn t Respond Two possibilities for this problem Have you registered the card to the terminal The card must be registered to the terminal before the terminal could read the information in the card Refer to chap ter 8 User page 29 for card enro...

Страница 24: ...Output Wiegand In Power Out Power In RS 485 Button Door Sensor Lock Alarm Bell RS 232 Ethernet WD 0 WD 1 GND RXD TXD GND 485 485 RJ45 1 RJ45 2 RJ45 3 RJ45 6 AL AL NC COM NO BUT GND SEN BELL BELL 12V GND 12V GND IWD 0 IWD 1 RLED GLED BEEP ...