background image

Continue to hold in 

the Power button 

then slowly slide unit 

horizontally across the 

wall, right or left. As 

you begin to approach 

a stud, the red LEDs 

will light successively, 

from bottom to top.

When the top green 

LED is lit, the SpotLite

®

 

beam shines, and a 

steady tone sounds, 

you have located the 

edge of the stud. 

Mark this spot.

Without releasing 

Power button, continue 

scanning beyond 

marked spot until 

green LED goes out. 

Slide unit in reverse 

direction to locate 

other edge of stud.

Mark this second spot.  

Middle of stud is 

centered between the 

two marks.

Squeeze sides 

of clip to help 

release clip end.

Slide 9-V battery 

into compartment, 

terminal side first, 

matching (+) and 

(–) terminals from 

battery to case.

Replace the clip. 

2. SELECTING THE MODE

Move selector switch to the desired mode: 

STUD SCAN for finding wood or metal studs or 

DEEPSCAN

®

 for finding studs behind walls more 

than ¾ inch (19 mm) thick.
Unit will remain off if Power button is not depressed.

3. FINDING A STUD

Always scan for studs with the scanner placed flat 

against the wall. Move the mode 

switch to STUD SCAN, place 

the tool flat against the wall, 

then press and hold the Power 

button. Wait for beep to confirm 

calibration has completed before 

moving scanner. 

1. INSTALLING THE BATTERY

NOTE:  DO NOT LOOSEN OR REMOVE 

SCREW ON THE BACK OF THE UNIT.

4. WIREWARNING

®

 DETECTION 

WireWarning

®

 detection works continuously in 

STUD SCAN and DEEPSCAN

®

 modes. When live 

AC voltage is detected, the WireWarning

®

 light 

comes on. If scanning begins over a live AC wire, 

the WireWarning

®

 indicator will flash continuously. 

Caution: Wires deeper than 2 in. (51 mm) from 

the surface, in plastic conduit, behind plywood 

shear wall, or metallic wall covering may not 

be detected. Use extreme caution in these 

circumstances or whenever live AC is present.

Always turn off the power when working near 

electrical wires.

5. OPERATING TIPS

For optimum scanning results:

• Hold the tool straight up and down, parallel to 

the studs, and do not rotate the tool.

• Keep tool flat against the wall and do not rock, 

tilt, or press hard when slowly sliding across the 

surface being scanned.

• Avoid placing your other hand, or any other 

part of your body, on the surface being scanned.

• Depending on the proximity of electrical wiring 

or pipes to the wall surface, the scanner may 

detect them in the same manner as studs. 

Caution should always be used when nailing, 

cutting, or drilling in walls, floors, and ceilings 

that may contain these items.

Lights start flashing 

and unit starts beeping.

Unable to detect studs in 

STUD SCAN mode.
Top green LED doesn’t 

light when scanning; only 

a few red LEDs light up.

The TruCal

®

 icon  

turns on but, when  

scanning, unit doesn’t  

do anything else.

Working in DEEPSCAN

®

 

mode and can’t detect 

studs.

Detects other objects 

besides studs.

You suspect electrical 

wires, but do not  

detect any. 

Area of voltage 

detection appears much 

larger than actual wire 

(AC only). 

• Scan began on dense part of wall or 

over a stud.

• Unit not flat against wall.
• Unit tilted or lifted during scan. 

(All these factors affect proper 

calibration.)

• Scanning surface is too dense or too 

wet for unit to operate.

• Wall is particularly thick or dense.

• Unit may not be flat against the 

wall.

• If it is in the DEEPSCAN

®

 mode 

(DEEPSCAN

®

 is lit), you may have 

calibrated over a stud.

• You may have calibrated over a 

stud. (The error condition is disabled 

in DEEPSCAN

®

 mode because it is 

twice as sensitive as STUD SCAN.) 

• You may be holding the unit like a 

TV remote, aiming it at the wall.

• Electrical wiring and metal or plastic 

pipes may be near or touching back 

surface of wall.

• Wires may be shielded behind 

metallic wall coverings, plywood 

shearwall, or other dense material, 

or in conduit.

• The wires may not be live.
• Wires deeper than 2 in. (51 mm) 

from surface may not be detected.

• Voltage detection can spread on 

drywall as much as 12 in. (305 mm)

 

from each side of an actual 

electrical wire.

• Turn unit off, move over a few inches, press Power 

button, and start again.

• On rough surfaces, place a thin piece of cardboard on 

wall, scanning over it to help slide unit more smoothly.

• Keep hand at least 6 in. (152 mm) from unit while you 

calibrate and scan. Hold unit with thumb and index 

finger no higher than handgrips. Be careful not to 

move your fingers after calibration.

• Always hold unit parallel to the stud and move it 

perpendicular to the stud you’re trying to locate.

• If you are using unit on a recently taped, painted, or 

wallpapered wall, allow time to dry and try again.

• Switch to DEEPSCAN

®

 mode to locate the stud.

• Interpret the the higest LED obtained as the stud edge.

• Hold unit so two Velcro

 strips on the back make  

contact with wall.

• Recalibrate unit in a different place and re-scan area.

• Move unit over a few inches and recalibrate.
• Hold unit so two Velcro

 strips on the back make 

contact with wall.

• Check for other studs equally spaced to either side

 

12, 16, or 24 in. (305, 406, or 610 mm) apart or for 

the same stud at several places directly above or 

below the first scan area.

• Use extra caution if the area has plywood, thick wood 

 

backing behind drywall, or thicker-than-normal walls. 

• If a switch controls an outlet, make sure it is ON for 

 

detection, but turned off when working near 

electrical wires.

Always turn off power when cutting, nailing, or 

drilling near electrical wires.

• To narrow detection, turn unit off and on again at the 

edge of where wire was detected and scan again.

Always turn off power when cutting, nailing, or 

drilling near electrical wires.

Probable  Causes

Solutions

Situation

• To avoid surprises, remember that studs or 

joists are normally spaced 16 in. (406 mm) or 

24 in. (610 mm) apart and are 1 ½ in. (38 mm) 

in width. Anything closer together or a different 

width may not be a stud, joist, or firebreak.

Always turn off the power when working near 

electrical wires.

WORKING WITH DIFFERENT MATERIALS

StudSensor

 Pro SL-AC is for use on dry interior 

walls only. 

Note: Sensing depth and accuracy can vary due 

to moisture, content of materials, wall texture, 

and paint. 

StudSensor

 Pro SL-AC can scan effectively 

through most sheet materials, including: 

• Bare wood flooring (in DEEPSCAN

®

 mode)

• Linoleum on wood base 
• Gypsum drywall over plywood sheathing 
• Wallpapered walls (if dry)
• Textured ceilings if uniform thickness (place a 

thin piece of cardboard on ceiling and scan over 

it to avoid damage to texturing) 

StudSensor

 Pro SL-AC is not designed to scan 

materials such as:

• Ceramic floor tile
• Carpeting and padding
• Wallpaper with metallic fibers
• Freshly painted walls that are still damp (may 

take one week or longer to dry after application)

• Lath and plaster walls 
• Foil covered insulation board
• Glass or any other dense material

StudSensor

 Pro SL-AC

Stud Finder

Stud Edge 

Groove

SpotLite

®

 

Pointing System

WireWarning

®

 

Detection

STUD SCAN 

Mode LED 

Power 

Button

TruCal

®

 LED

DEEPSCAN

®

 

Mode LED

Mode Switch

DeepScan, SpotLite, StudSensor, TruCal, WireWarning, and Zircon are registered trademarks or trademarks of Zircon Corporation.

Visit www.zircon.com/support for the most current instructions.

6. HELPFUL HINTS

 

(See also number 5, Operating Tips)

 

The StudSensor

 Pro SL-AC features two 

scanning modes:

• STUD SCAN: Locates the edges of wood 

and metal studs up to ¾ in.  

(19 mm) deep

• DEEPSCAN

®

: Locates the edges of wood 

and metal studs up to 

1 ½

 in. 

(38 mm) deep

WireWarning

®

 detection automatically 

detects and alerts the user to live AC 

wires in STUD SCAN and DEEPSCAN

®

 

modes. When AC voltage is detected, the 

AC WireWarning

®

 icon will be displayed 

on screen.

Note: This product is intended 

for use in the U.S.A. and 

Canada only.

LIMITED 1 YEAR WARRANTY
Zircon Corporation, (“Zircon”) warrants this product to be free from defects 

in materials and workmanship for one years from the date of purchase. Any 

in-warranty defective product returned to Zircon*, freight prepaid with proof 

of purchase date and $5.00 to cover postage and handling, will be repaired or 

replaced at Zircon’s option. This warranty is limited to the electronic circuitry and 

original case of the product and specifically excludes damage caused by abuse, 

unreasonable use or neglect. This warranty is in lieu of all other warranties, express 

or implied, and no other representations or claims of any nature shall bind or 

obligate Zircon. Any implied warranties applicable to this product are limited to 

the one year period following its purchase. IN NO EVENT WILL ZIRCON BE LIABLE 

FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM 

POSSESSION, USE OR MALFUNCTION OF THIS PRODUCT.

In accordance with government regulations, you are advised that: (i) some states 

do not allow limitations on how long an implied warranty lasts and/or the exclusion 

or limitation of incidental or consequential damages, so the above limitations and/

or exclusions may not apply to you, and further (ii) this warranty gives you specific 

legal rights and you may also have other rights which vary from state to state.

Return product freight prepaid with proof of purchase date (dated 

sales receipt) and $5.00 to cover postage and handling, to:

Zircon Corporation 

*Attn: Returns Department 

1580 Dell Avenue

 

Campbell, CA 95008-6992 USA
Be sure to include your name and return address. Out of warranty 

service and repair, where proof of purchase is not provided, shall be 

returned with repairs charged C.O.D. Allow 4 to 6 weeks for delivery.
Customer Service, 1-800-245-9265 or 1-408-963-4550

 

Monday–Friday, 8:00 a.m. to 5:00 p.m. PDT

 

www.zircon.com • [email protected]
U.S. Patents 5352974, 5619128, 6023159, 6259241, 6291970,

 

Canadian Patents 2141553, 2341385, 2353156, Japanese Patent 

3581851, E.U. Patents Pending, German Patent 69333884.9,

 

French Patent 0657032, U.K. Patent 0657032 
©2009 Zircon Corporation • P/N 59459 • Rev C 06/09

FCC Part 15 Class B Registration Warning

This device complies with Part 15 of FCC Rules.  

Operation is subject to the following two conditions: 

(1) this device may not cause harmful interference, and 

(2) this device must accept any interference received, 

including interference that may cause undesired operation.

Отзывы: