ZIPPER MASCHINEN GmbH www.Zipper-Maschinen.at
31
ZI-RPE120GYN
16.4
Stopping the Machine
16.4.1
Emergency Stop
In case of danger and/or in an emergency situation, you can quickly switch off the vibratory
plate with the speed governor by pushing it completely into the S
TOP
position.
16.4.2
Switching off the machine
1.
Set the upper throttle lever to "minimum" and let the engine run idle for approx. 3
minutes at low engine speed.
2.
Then set the engine O
N
/O
FF
switch (ignition switch) to the O
FF
position.
3.
Close the fuel switch.
4.
Wait until the engine has cooled down before storing the machine.
17
MAINTENANCE
W A R N I N G
Hot surfaces and rotating machine parts while the engine is running can cause
serious injury or even death. Always switch off the machine for conversion,
adjustment, cleaning and maintenance work and secure it against unintentional start-
up.
17.1
Maintenance and servicing plan
17.1.1
Table of Activities
What to do?
When to do / how often?
Check fuel level
before each start-up
Check engine oil level
before each start-up
Control of the operating elements
before each start-up
Check for damaged parts
before each start-up
Checking for loose or lost screws
before each start-up
Change engine oil
first after 20 h, then every 100 h
Check V-belt
every 50 h; replacement after 300 h or 1
year
Change exciter oil
every 200 h
air filter cleaning
every 50 h, replacement after 300 h or 1
year
spark plug test
every 100 h; replacement after 300 h or 1
year
The specified intervals refer to working under "normal" operating conditions. Depending on the
load, a change/exchange may also be necessary at an earlier point in time.