The device will measure the temperature in every minute. And if
the temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device will always report each measurement.
Caution 1:
Enabling this functionality will cause the PIR Motion to
disable detection when it measuress the temperature. In other words,
The PIR motion will be blind second per every minute.
ILLUMINATION REPORT
When the PIR motion detected or the door/window state changed, the
device will unsolicitedly send the “Sensor Multilevel Report” to the
nodes in the group 1.
Sensor Type: Luminance (0x03)
Note: To disable this functionality set the the configuration setting
N0.5, the bit4 of the value to 1.
Illumination differential report
This function is disabled by default, to enable this function set the
configuration NO.22 to value other than zero. When this functionality
is enabled, the device will measure the illumination in every minute. If
the illumination is changed to plus or minus the value (setting by the
configuration NO.22), the device will report illumination information to
the nodes in the group 1.
Caution 1:
Enabling this function will reduce the battery life about 15%
~ 20%. Additionally, if you set the differential value too small, it
will increase reporting frequency, which will shorten the battery life
more. We reccommend that differential value should not be smaller
than 10. value should not small than 10.
Caution 2:
If the configuration No.4 is setting to 0 or 100, this
functionality is useless.
Caution 3:
Enabling this functionality will cause the PIR Motion to
disable detection during the illumination measurement. In other
words, the PIR motion will go blind per one second in every minute.
TIMING REPORT
Beside the event triggered could report message, the device also
supports the timing of unsolicited status reporting.
Battery level report: Every 6 hours report once in default. It could
be changed by configuration setting NO. 10.
Low battery report: When the battery level is too low, every 30
minutes report will be sent once.
Door/window state report: Every 6 hours report is sent once by
default. It can be changed in configuration setting NO. 11.
Illumination level report: Every 6 hours report will be sent once by
default. It can be changed in configuration setting NO. 12.
Temperature report: Every 6 hours report once in default. It could
be changed by configuration setting NO. 13.
Notice:
The configuration NO. 10, 11, 12 and 13 can be set to zero
to disable the auto report. Configuration NO. 20 can change the tick
interval, the default value is 30, if setting to 1, that means the minimum
auto report interval will be one minute. And please notice if setting this
value to zero, that means disable all of the timing report except the
low battery detection.
Z-WAVE CONFIGURATION SETTINGS
Notice:
For
all of the configuration, the data size is 1.
The configuration marked with star(*), means that after the
removal of device, setting will still keep, without reverting back
to factory default settings. Unless the user execute the “RESET”
procedure.
The reserve bit or not supported bit is allowed any value, but no
effect.
NO.
Name
Def.
Valid
Values
Description
2
Basic Set
Level
0xFF All
Setting the BASIC
command value to
turn on the light.
The 0xFF(-1) means
turn on the light. For
dimmer equipment 1
to 100 means the light
strength.
3
(*)
PIR
Sensitivity
80
0~99
PIR sensitivity settings.
0 means disable the
PIR motion.
1 means the lowest
sensitivity,
99 means the highest
sensitivity.
High sensitivity means
can detected long
distance, but if there is
more noise signal
in the environment, it
will re-trigger too
frequency.
4
Light
Threshold
99
0~100
Setting the illumination
threshold to turn
on the light. When
the event triggered
and the environment
illumination lower
then the threshold, the
device will turn
on the light.
0 means turn off
illumination detected
function. And never
turn on the light.
1 means darkest.
99 means brightest.
100 means turn off
illumination detected
function. And always
turn on the light.
Notice:
In none test
mode, only the
value in 1 to 99 will
enable the
illumination detected
function and
update the illumination
value.
5
Operation
Mode
0
All
Operation mode. Using
bit to control.
Bit0: Reserve.
Bit1: 1 means test
mode, 0 means normal
mode.
Notice: This bit only
effect by the DIP Switch
setting to “customer
mode”, otherwise it
decides by DIP Switch
setting to Test or
Normal Mode.
Bit2: Disable the door/
window function.
(1:Disable, 0:Enable)
Bit3: Setting the
temperature scale.
0: Fahrenheit, 1:Celsius
Bit4: Disable the
illumination report
after event triggered.
(1:Disable, 0:Enable)
Bit5: Disable the
temperature report
after event triggered.
(1:Disable, 0:Enable)
Bit6: Reserve.
Bit7: Disable the back
key release into test
mode. (1:Disable,
0:Enable)
6
(*)
Multi-Sensor
Function
Switch
4
All
Multisensor function
switch. Using bit
to control.
0
All
Bit0: Disable magnetic
integrate illumination to
turn ON the lighting
nodes in the association
group 2.
(1:Disable, 0:Enable)
Bit1: Disable PIR
integrate Illumination to
turn ON the lighting
nodes in the association
group 2.
(1:Disable, 0:Enable)
1
All
Bit2: Disable magnetic
integrate PIR to turn
ON the lighting nodes
in the association group
2. (1:Disable, 0:Enable)
(Default is Disable)
0
All
Bit3: When Bit2 is 0
(Enable), Are the device
and the lighting in the
same room?
0: In the same room
(Default),
1: In the different room.
Notice: If this bit is 1,
it is recommended
also set the Bit1 to 1,
cause the PIR triggered,
doesn’t mean the
people in that room.
Bit4: Disable delay
5 seconds to turn
off the light, when
door/window closed.
(1:Disable, 0:Enable)
Bit5: Disable auto turn
off the light, after door/
window opened to turn
on the light. (1:Disable,
0:Enable)
Notice: If bit2 is zero,
this setting is useless.
Notice: If the
configuration No.9 is
zero, this setting is
useless.
7
(*)
Customer
Function
4
All
Customer function
switch, using bit control.
0
All
Bit1: Enable sending
motion OFF report.
(0:Disable, 1:Enable)
Note: Depends on
the Bit4, 0: Report
Notification CC, Type:
0x07, Event: 0xFE
1: Sensor Binary
Report, Type: 0x0C,
Value: 0x00
1
All
Bit2: Enable PIR super
sensitivity mode.
(0:Disable, 1:Enable)
0
All
Bit3: Disable send out
BASIC OFF after door
closed. (1:Disable,
0:Enable)
Bit4: Notification Type,
0: Using Notification
Report. 1: Using Sensor
Binary Report. Bit5:
Disable Multi CC in
auto report. (1:Disable,
0:Enable) Bit6: Disable
to report battery
state when the device
triggered. (1:Disable,
0:Enable)
8
PIR Re-
Detect
Interval Time
3
1~127
In the normal mode,
after the PIR motion
detected, setting
the re-detect time.
8 seconds per tick,
default tick is 3 (24
seconds). Setting
the suitable value to
prevent received the
trigger signal too
frequently. Also can
save the battery energy.
Notice: If this value
bigger than the
configuration setting
NO. 9. There is a
period after the light
turned off and the PIR
not start detecting.
9
Turn Off
Light
Time
4
0~127
After turn on the
lighting, setting the
delay time to turn
off the lighting when
the PIR motion is not
detected. 8 seconds per
tick, default tick is 4 (32
seconds).
0 means never send
turn off light command.
10
Auto Report
Battery Time
12
0~127
The interval time for
auto report the battery
level. 0 means turn off
auto report battery.
The default value
is 12. The tick time
can setting by the
configuration No.20.
11
Auto Report
Door/
Window
State Time
12
0~127
The interval time for
auto report the door/
window state. 0 means
turn off auto report
door/window state. The
default value is 12. The
tick time can setting
by the configuration
No.20.
12
Auto Report
Illumination
Time
12
0~127
The interval time
for auto report the
illumination. 0 means
turn off auto report
illumination. The
default value is 12. The
tick time can setting
by the configuration
No.20.
13
Auto Report
Temperature
Time
12
0~127
The interval time for a
20
Auto Report
Tick Interval
30
0 ~
0xFF
The interval time
for auto report each
tick. Setting this
configuration will
effect configuration
No.10, No.11, No.12
and No.13. Caution:
Setting to 0 means
turn off
all auto report function.
21
Temperature
Differential
Report
1
0 ~
0x7F
The temperature
differential to report.
0 means turn off this
function. The unit is
Fahrenheit. Enable this
function the device will
detect every minutes.
And when the
temperature is over 140
degree Fahrenheit, it
will continue report.
Enable this
functionality will cause
some issue please
see the detail in the
“Temperature Report”
section.
make your home smart
www.zipato.com
make your home smart
www.zipato.com
03