background image

The device will measure the temperature in every minute. And if
the temperature is over 140 degree Fahrenheit (60 degree Celsius), the
device will always report each measurement.

Caution 1:

 Enabling this functionality will cause the PIR Motion to 

disable detection when it measuress the temperature. In other words, 
The PIR motion will be blind second per every minute.

 ILLUMINATION REPORT

When the PIR motion detected or the door/window state changed, the 
device will unsolicitedly send the “Sensor Multilevel Report” to the 
nodes in the group 1.

Sensor Type: Luminance (0x03)
Note: To disable this functionality set the the configuration setting 
N0.5, the bit4 of the value to 1.

Illumination differential report

This function is disabled by default, to enable this function set the 
configuration NO.22 to value other than zero. When this functionality 
is enabled, the device will measure the illumination in every minute. If 
the illumination is changed to plus or minus the value (setting by the 
configuration NO.22), the device will report illumination information to 
the nodes in the group 1.

Caution 1: 

Enabling this function will reduce the battery life about 15%

~ 20%. Additionally, if you set the differential value too small, it
will increase reporting frequency, which will shorten the battery life 
more. We reccommend that differential value should not be smaller 
than 10. value should not small than 10.

Caution 2:

 If the configuration No.4 is setting to 0 or 100, this

functionality is useless.

Caution 3: 

Enabling this functionality will cause the PIR Motion to 

disable detection during the illumination measurement. In other 
words, the PIR motion will go blind per one second in every minute.

 TIMING REPORT

Beside the event triggered could report message, the device also 
supports the timing of unsolicited status reporting.

 Battery level report: Every 6 hours report once in default. It could 
be changed by configuration setting NO. 10.
 Low battery report: When the battery level is too low, every 30 
minutes report will be sent once.
 Door/window state report: Every 6 hours report is sent once by 
default. It can be changed in configuration setting NO. 11.
 Illumination level report: Every 6 hours report will be sent once by 
default. It can be changed in configuration setting NO. 12.
 Temperature report: Every 6 hours report once in default. It could 
be changed by configuration setting NO. 13.

Notice: 

The configuration NO. 10, 11, 12 and 13 can be set to zero 

to disable the auto report. Configuration NO. 20 can change the tick 
interval, the default value is 30, if setting to 1, that means the minimum 
auto report interval will be one minute. And please notice if setting this 
value to zero, that means disable all of the timing report except the 
low battery detection.

Z-WAVE CONFIGURATION SETTINGS

Notice:

For

 

all of the configuration, the data size is 1.

 The configuration marked with star(*), means that after the 
removal of device, setting will still keep, without reverting back 
to factory default settings. Unless the user execute the “RESET” 
procedure.
 The reserve bit or not supported bit is allowed any value, but no 
effect.

NO.

Name

Def.

Valid

Values

Description

2

Basic Set 

Level

0xFF All

Setting the BASIC 

command value to

turn on the light. 

The 0xFF(-1) means 

turn on the light. For 

dimmer equipment 1 

to 100 means the light 

strength.

(*)

PIR 

Sensitivity

80

0~99

PIR sensitivity settings.

0 means disable the 

PIR motion.

1 means the lowest 

sensitivity,

99 means the highest 

sensitivity.

High sensitivity means 

can detected long

distance, but if there is 

more noise signal

in the environment, it 

will re-trigger too

frequency.

4

Light

Threshold

99

0~100

Setting the illumination 

threshold to turn 

on the light. When 

the event triggered 

and the environment 

illumination lower

then the threshold, the 

device will turn

on the light.

0 means turn off 

illumination detected

function. And never 

turn on the light.

1 means darkest.

99 means brightest.

100 means turn off 

illumination detected

function. And always 

turn on the light.

Notice:

 In none test 

mode, only the

value in 1 to 99 will 

enable the

illumination detected 

function and

update the illumination 

value.

5

Operation

Mode

0

All

Operation mode. Using 

bit to control.

Bit0: Reserve.

Bit1: 1 means test 

mode, 0 means normal 

mode.

Notice: This bit only 

effect by the DIP Switch 

setting to “customer 

mode”, otherwise it 

decides by DIP Switch 

setting to Test or 

Normal Mode.

Bit2: Disable the door/

window function. 

(1:Disable, 0:Enable)

Bit3: Setting the 

temperature scale.

0: Fahrenheit, 1:Celsius

Bit4: Disable the 

illumination report

after event triggered. 

(1:Disable, 0:Enable)

Bit5: Disable the 

temperature report

after event triggered. 

(1:Disable, 0:Enable)

Bit6: Reserve.

Bit7: Disable the back 

key release into test 

mode. (1:Disable, 

0:Enable)

(*)

Multi-Sensor

Function

Switch

4

All

Multisensor function 

switch. Using bit

to control.

0

All

Bit0: Disable magnetic 

integrate illumination to 

turn ON the lighting

nodes in the association 

group 2.

(1:Disable, 0:Enable) 

Bit1: Disable PIR 

integrate Illumination to 

turn ON the lighting

nodes in the association 

group 2.

(1:Disable, 0:Enable)

1

All

Bit2: Disable magnetic 

integrate PIR to turn 

ON the lighting nodes 

in the association group 

2. (1:Disable, 0:Enable) 

(Default is Disable)

0

All

Bit3: When Bit2 is 0 

(Enable), Are the device 

and the lighting in the 

same room?

0: In the same room 

(Default),

1: In the different room.

Notice: If this bit is 1, 

it is recommended 

also set the Bit1 to 1, 

cause the PIR triggered, 

doesn’t mean the 

people in that room. 

Bit4: Disable delay 

5 seconds to turn 

off the light, when 

door/window closed. 

(1:Disable, 0:Enable) 

Bit5: Disable auto turn 

off the light, after door/

window opened to turn 

on the light. (1:Disable, 

0:Enable)

Notice: If bit2 is zero, 

this setting is useless. 

Notice: If the 

configuration No.9 is

zero, this setting is 

useless.

(*)

Customer

Function

4

All

Customer function 

switch, using bit control.

0

All

Bit1: Enable sending 

motion OFF report. 

(0:Disable, 1:Enable)

Note: Depends on 

the Bit4, 0: Report 

Notification CC, Type: 

0x07, Event: 0xFE

1: Sensor Binary 

Report, Type: 0x0C, 

Value: 0x00

1

All

Bit2: Enable PIR super 

sensitivity mode. 

(0:Disable, 1:Enable)

0

All

Bit3: Disable send out 

BASIC OFF after door 

closed. (1:Disable,

0:Enable) 

Bit4: Notification Type,

0: Using Notification 

Report. 1: Using Sensor 

Binary Report. Bit5: 

Disable Multi CC in 

auto report. (1:Disable, 

0:Enable) Bit6: Disable 

to report battery 

state when the device 

triggered. (1:Disable, 

0:Enable)

8

PIR Re-

Detect

Interval Time

3

1~127

In the normal mode, 

after the PIR motion 

detected, setting 

the re-detect time. 

8 seconds per tick, 

default tick is 3 (24 

seconds). Setting 

the suitable value to 

prevent received the 

trigger signal too

frequently. Also can 

save the battery energy.

Notice: If this value 

bigger than the

configuration setting 

NO. 9. There is a

period after the light 

turned off and the PIR 

not start detecting.

9

Turn Off 

Light

Time

4

0~127

After turn on the 

lighting, setting the

delay time to turn 

off the lighting when 

the PIR motion is not 

detected. 8 seconds per 

tick, default tick is 4 (32 

seconds).

0 means never send 

turn off light command.

10

Auto Report

Battery Time

12

0~127

The interval time for 

auto report the battery 

level. 0 means turn off 

auto report battery.

The default value 

is 12. The tick time 

can setting by the 

configuration No.20.

11

Auto Report

Door/

Window

State Time

12

0~127

The interval time for 

auto report the door/

window state. 0 means 

turn off auto report

door/window state. The 

default value is 12. The 

tick time can setting 

by the configuration 

No.20.

12

Auto Report

Illumination

Time

12

0~127

The interval time 

for auto report the 

illumination. 0 means 

turn off auto report 

illumination. The 

default value is 12. The 

tick time can setting 

by the configuration 

No.20.

13

Auto Report

Temperature

Time

12

0~127

The interval time for a

20

Auto Report

Tick Interval

30

0 ~

0xFF

The interval time 

for auto report each 

tick. Setting this 

configuration will

effect configuration 

No.10, No.11, No.12 

and No.13. Caution: 

Setting to 0 means 

turn off

all auto report function.

21

Temperature

Differential

Report

1

0 ~

0x7F

The temperature 

differential to report.

0 means turn off this 

function. The unit is 

Fahrenheit. Enable this 

function the device will

detect every minutes.

And when the 

temperature is over 140

degree Fahrenheit, it 

will continue report.

Enable this 

functionality will cause 

some issue please 

see the detail in the 

“Temperature Report” 

section.

make your home smart

www.zipato.com

make your home smart

www.zipato.com

03