Zip VP103 Скачать руководство пользователя страница 1

Contents

Zip Varipoint II Installation, Maintenance and User Instructions - June 2004    

3

Specification

4

Special notices

5

Dimensions

6

Installation

Requirements

7-8

Positioning

9

Plumbing

9

Electrical

10

Commissioning

10-11

Operation

Precautions

11-12

Maintenance

Schedule

13

Fault Finding

13

De-Install

13

Spare Parts

14

Содержание VP103

Страница 1: ...Instructions June 2004 3 Specification 4 Special notices 5 Dimensions 6 Installation Requirements 7 8 Positioning 9 Plumbing 9 Electrical 10 Commissioning 10 11 Operation Precautions 11 12 Maintenanc...

Страница 2: ...ation High density CFC free polyurethane foam Safety features Expansion relief valve supplied Manually resettable over temperature safety cutout Facility for optional T P valve Water heater protected...

Страница 3: ...s constructed from impact resistant plastic and heat losses are minimised by the CFC free polyurethane foam insulation The inner vessel is heavy gauge copper and pressure tested to 16 Bar An alloy she...

Страница 4: ...Weight kg Under Basin litres A B C Empty Full VP103 Over 10 452 300 285 6 5 16 5 VP103UB Under 10 452 300 285 6 5 16 5 VP153 Over 15 452 300 285 7 5 22 5 VP153UB Under 15 452 300 285 7 5 22 5 6 Zip V...

Страница 5: ...s under 4 bars fit accessory pack AQ2 Expansion vessel and check valve Where static water pressures are likely to exceed 4 bars fit accessory packs AQ2 and AQ3 Pressure reducing valve and line straine...

Страница 6: ...is greater than 4 bar and expanded water cannot be accommodated in the pipework Using pack AQ2 and AQ3 expansion vessel check valve and pressure reducing valve 8 Zip Varipoint II Installation Mainten...

Страница 7: ...Zip Heaters on 0870 608 8888 5 Position the Zip Varipoint to allow for future maintenance 6 Do not install in a location where the unit or connecting pipe can freeze Plumbing 1 Check the incoming wat...

Страница 8: ...ver by sliding forwards d Pass the new cable through the entry point of the cover e Remake the connections f Ensure the cable is securely clamped g Refasten the cover Do not switch on the electrical s...

Страница 9: ...inst frost damage but this protection does not extend to connecting pipework or fittings Economy setting Standard setting Setting for very hot water when large amounts of warm water mixed hot and cold...

Страница 10: ...should be visually inspected regularly This is particularly important if the heater is located in a cupboard roof space or any other concealed location If there is any sign of leaks or seepage the hea...

Страница 11: ...Possible causes Water not heating 1 Electricity supply fault 2 Over temperature cut out tripped 3 Faulty thermostat 4 Faulty element Discharge from 1 Thermostat fault any relief valve 2 Excessive main...

Страница 12: ...asin Item Part No Description 1 VP0301 Element 2 2kW 2 VP0303 Thermostat 3 VP0304 Resettable Cut Out 4 VP0317 Element Gasket 5 VP0322 Wall Fixing Bracket Zip Varipoint II Underbasin Item Part No Descr...

Страница 13: ...is not due to accident misuse abuse condition of the water frost or failure to follow installation instructions or service requirements The only charges payable by the customer are the cost or removal...

Отзывы: