Zip VARIPOINT II Series Скачать руководство пользователя страница 1

1

INSTALLATION INSTRUCTIONS & USER MANUAL 

210006 V2.00 SEPT 2017 - ZIP VPII/103-153(UB)

TECHNICAL SUPPORT

 TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK   

WWW.ZIPWATER.CO.UK

ZIP  

VARIPOINT II

INSTALLATION INSTRUCTIONS & USER MANUAL 

MODEL NUMBER:

 

VP103, VP153, VP103UB & VP153UB

Direct unvented water heaters.

Содержание VARIPOINT II Series

Страница 1: ...2 00 SEPT 2017 ZIP VPII 103 153 UB TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK ZIP VARIPOINTII INSTALLATION INSTRUCTIONS USER MANUAL MODEL NUMBER VP103 VP153 VP103UB VP153UB Direct unvented water heaters ...

Страница 2: ...peration 14 Maintenance 15 Precautions 15 Schedule 16 De installation 16 Fault finding 17 End of life disposal 18 Warranty 19 Contact details 20 Please read these instructions carefully before commencing installation of this unvented water heater Installation must only be undertaken by a competent person familiar with unvented electric water heaters The Zip Varipoint II must be installed in accord...

Страница 3: ...oam insulation The inner vessel is constructed from heavy gauge copper and pressure tested to 1 6 MPa 16 bar maximum working pressure 0 55 MPa 5 5 bar A manually resettable safety cut out automatically cuts off the electrical supply to the heating element in the event of a malfunction If the hot water system is not used for two weeks or more it is recommended that a hot tap be turned on for severa...

Страница 4: ... Installation Overbasin Underbasin Overbasin Underbasin Declared load profile XXS XXS XXS XXS Energy efficiency class 1 A B A A Energy efficiency ηwh 1 35 5 34 7 35 4 36 2 Annual electricity consumption 1 kWh 502 530 521 510 Thermostat temperature setting ºC 35 Max temperature ºC 80 Specific precautions See installation and operating instructions Smart value 0 Rated volume l 10 0 15 0 Weight empty...

Страница 5: ...uately secured This appliance must be earthed at all times Check that the power supply is switched off prior to electrical connection The appliance its wiring and piping must not be modified in any way Do not remove the cover whilst the unit is connected to the electricity supply In case of malfunction isolate the power supply immediately In case of leaks also isolate the water supply Repairs must...

Страница 6: ... block or restrict the discharge from any safety valve Do not tamper with any safety valve SAFETY INFORMATION CAUTIONS The appliance must only be used when correctly installed and in perfect working order The appliance must be installed in a frost free room and must never be exposed to frost The Zip Varipoint II range is not recommended for use with secondary circulation systems The appliance must...

Страница 7: ...L 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK REF ITEM DESCRIPTION 1 VP0301 Element 2 2 kW for overbasin models 1 VP0302 Element 2 2 kW for underbasin models 2 VP0303 Thermostat 3 VP0304 Ressettable cut out 4 VP0317 Element Gasket 5 VP0322 Wall fixing bracket SPARE PARTS 1 4 5 2 3 ...

Страница 8: ...K WWW ZIPWATER CO UK Please check that the items listed below have been supplied in the Varipoint II pack ITEM QTY Wall Bracket 1 Temperature and Pressure Valve 1 Expansion Relief Valve 1 2 BSP 1 Expansion vessel and check valve Combined pressure reducer and line strainer Thermostatic blending valve TMV2 TMV3 rated Water block PACK CONTENTS ACCESSORIES ...

Страница 9: ...tatic water pressures are likely to exceed 3 5 bar fit accessory pack AQ2 and AQ3 pressure reducing valve and line strainer See diagrams 2 3 Fig 2 page 12 The temperature and pressure relief valve supplied may be fitted to the locating point provided The 6 bar expansion relief valve must be fitted on the cold water supply Under no circumstances should the expansion relief valve be installed in an ...

Страница 10: ...ed on the floor or cupboard base but if additional support is required securing screws are supplied that locate to the rear of the casing As shown in Fig 1 below Always position the Varipoint II to allow for its removal for future inspection and maintenance The Varipoint II is not recommended for installation above false ceilings Do not install in a location where this unit or connecting pipelines...

Страница 11: ...rmine the accessories required to suit your layout Position the heater and controls to allow for future maintenance All control and safety valves are marked with the direction of flow and will not function if incorrectly orientated Do not break any seals or attempt to adjust any safety valve to do so may impair the safety of the installation and will invalidate the warranty To ensure a watertight ...

Страница 12: ...alve and pressure reducing valve COLD WATER SUPPLY TO DRAIN VIA TUNDISH Length A COLD WATER DRAW OFF Minimum length of pipe Length A 10 Litres 2 7m 9ft 1 2m 4ft 15 Litres 4 2m 14ft 1 8m 6ft SIZE 15mm Pipe 22mm Pipe PRESSURE TEMPERATURE VALVE TO BE DRAINED VIA TUNDISH optional not supplied PRESSURE TEMPERATURE VALVE TO BE DRAINED VIA TUNDISH optional not supplied PRESSURE TEMPERATURE VALVE TO BE DR...

Страница 13: ...perature control knob off the spindle and release the screw underneath Remove the cover by sliding the it forwards then remove Disconnect the cable from the connector block and remove it Pass the new cable back through the entry port and locking maze then connect the cable to the connector block Slide the cover back on and screw into position ensuring the cable is clamped correctly Replace the con...

Страница 14: ...AND OPERATION Fig 4 This setting protects the appliance against frost damage but this protection does not extend to the connecting pipework and fittings NB The water heater cannot be switched off via the temperature selector It can only be switched off at the isolating switched mains supply socket ZIP Varipoint II Fig 3 Temperature Limitation Turn the temperature selector to the position shown in F...

Страница 15: ...e supply The over temperature safety cut out reset is located inside the cover DO NOT reset the over temperature cut out until the cause of it s operation has been correctly diagnosed and corrected DO NOT use the water heater if it is suspected of being frozen Switch off the electrical supply if water ceases to flow and do not switch it back on until a competent person electrician or plumber has c...

Страница 16: ... the components to be inspected should include the following Expansion relief valve Check correct operation T P relief valve if fitted Check correct operation Expansion vessel if fitted Check pressure referring to label on the side of the vessel Integral line strainer if a pressure reducing valve is fitted Inspect and clean as necessary Check the discharge pipe is free of obstructions Check that a...

Страница 17: ...d re commission Thermostat failure Isolate the heating system and check the thermal controls when discharge ceases Replace the thermostat if faulty Continuous water discharge from tundish Pressure reducing valve not operating correctly Check with pressure gauge and replace as necessary T P relief valve not operating correctly Check and replace if faulty Expansion relief valve not operating correct...

Страница 18: ...ndicates that this product needs to be disposed of separately to any other household waste Within each of the European Union member countries provisions have been made for the collection and recycling of unwanted electrical and electronic equipment In order to preserve our environment we ask that you dispose of this product correctly Please contact Zip Customer Service for advice on 0345 6 005 005...

Страница 19: ...ce Provider or the cost of removal cartage and re installation of any component of the appliance if it needs to be returned for repair to Zip or its distributor This warranty does not cover damage resulting from non operation of the appliance or consequential damage to any other goods furnishings or property Zip does not exclude restrict or modify any liability that cannot be excluded restricted o...

Страница 20: ...006 V2 00 SEPT 2017 ZIP VPII 103 153 UB TECHNICAL SUPPORT TEL 0345 6 005 005 EMAIL SERVICE ZIPINDUSTRIES CO UK WWW ZIPWATER CO UK Zip Water UK 14 Bertie Ward Way Dereham Norfolk NR19 1TE 0345 6 005 005 sales zipindustries co uk www zipwater co uk ...

Отзывы: