03

807042 v1.00 03.21 HydroTap G5 UltraCare Install Instruct

WARNINGS AND PRECAUTIONS

1.  For continued safety of this appliance it must be installed, 

operated and maintained in accordance with the 

manufacturer’s instructions.

2.  This appliance may deliver water at high temperature. Refer 

to the Plumbing Code of Australia (PCA), local requirements 

and  installation  instructions  to  determine  if  additional  delivery             

temperature control is required.

3.  Plumbing and electrical connections must be made in 

accordance with local regulations and relevant standards. In Australia: 

Plumbing standard AS/NZS 3500 & Electrical Wiring Rules AS/NZS 3000.

4.  This appliance must be earthed.
5.  The power cord and general power outlet must be in a safe, accessible 

position after installation. When positioning the appliance, ensure the 

power supply cord is not trapped or damaged. If the power supply cord 

is damaged it must be replaced by a Zip service provider or a qualified 

electrician.

6.  Use only the power supply provided with the UV-C Module. An 

ACM36US21 power supply is provided.

7.  Do not locate multiple portable socket-outlets or portable power 

supplies at the rear of the appliance.

8.  Do not remove the cover of the appliance under any circumstances 

without first isolating the appliance from the power supply.

9.  This unit is designed for indoor use and must not be installed outdoors 

or exposed to the elements of nature. 

10.  This unit must be installed with adequate clearances of 50mm on all 

sides, and 200mm above. Additional means of ventilation is critical if the 

vent kit, as supplied, cannot be fitted.

11.  Flush water supply lines before any plumbing connections are made, to 

prevent sediment from affecting operation.

12.  This unit must not be cleaned by a water jet. This unit must not be 

positioned in an area that may be cleaned by a water jet.

13.  This appliance is intended to be used in: staff kitchen areas in shops, 

offices and other working environments; farm houses and by clients in 

hotels, motels and other residential type environments; bed and breakfast 

type environments; catering and similar non-retail applications.

14.  For safe operation, the HydroTap is designed to be installed, 

commissioned and used within 48 hours. Should the HydroTap not be 

required for an extended period of time (72 hours or more), do not fill 

and commission the HydroTap until ready for first use.

!

Содержание UltraCare BCU40

Страница 1: ...1 807042 v1 00 03 21 HydroTap G5 UltraCare Install Instruct Model UltraCare BCU40 Installation Instructions Zip HydroTap G5 PRODUCTLABEL Visit our website to download the manuals Australia...

Страница 2: ...19 Cleaning 19 End of life disposal 19 Thank you for choosing Zip HydroTap Enjoy filtered boiling and chilled water from the Zip HydroTap The HydroTap Command Centre installed under the bench has a co...

Страница 3: ...ple portable socket outlets or portable power supplies at the rear of the appliance 8 Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the po...

Страница 4: ...technician To avoid hazards all installation procedures must be carried out by a suitably qualified tradesperson Venting Occasionally steam and or boiling water may discharge through a vent outlet on...

Страница 5: ...ses Classic tap shown part no 91519 BC chrome 1 x HydroTap Command Centre including water filter cartridge 1 x mains water braided hose part no 90056 Side Duct part no 91505 Vent Kit BC Model 1 x Inle...

Страница 6: ...ving jurisdiction The system is only designed to reduce normally occurring non pathogenic nuisance microorganisms Class B systems are not intended for treatment of contaminated water UltraCare BCU40 C...

Страница 7: ...are required The appliance must be connected to a potable water supply with min max working pressure as outlined in the Technical specifications with isolating valve within reach of the hose and posit...

Страница 8: ...Tap Command Centre Mains power supply to Command Centre Power for UV C Module Vent tray Side duct Mains water inlet isolation valve not supplied Step 1 Positioning Ensure there is adequate space in th...

Страница 9: ...out in cabinet oor Inlet vent options Fit the silicone door buffers to the inside edge of the cupboard door to provide an air space Step 2 Ventilation IMPORTANT Allow a minimum clearance envelope of...

Страница 10: ...ted with a drain 3 1 Pass the hoses down through the hole and locate the tap in place 3 4 From below the benchtop push the washer over the hoses and threaded rod then push the spider clamp onto the th...

Страница 11: ...Flush water supply lines before any plumbing connections are made to prevent sediment from affecting operation Connect electrical cable to the side of the Command Centre Power must remain OFF until co...

Страница 12: ...UE hose from tap Push at least 15mm over the fitting Connect USB C cable from UV C Module to HydroTap Ensure hose has constant fall Connect 12V power supply to HydroTap Power must remain OFF until com...

Страница 13: ...ection Push the hose over the connector for a minimum of 15mm There a constant fall from the tap down to the Command Centre Hoses must be trimmed to avoid loops and kinks Take care when positioning be...

Страница 14: ...filter factory setting With external filter Set bypass valve optional The bypass valve diverts the boiling feed water to external filtration optional internal filter is supplied with the unit The valv...

Страница 15: ...urn electrical power ON at both the power outlets 6 2 Step 6 Commissioning 10L bucket not supplied Open valve to let water flow Close valve when complete Do not commission your HydroTap until it is re...

Страница 16: ...ch requires the product to be flushed with fresh water at installation as shown on the Command Centre screen Each tank boiling and chilled must be emptied and filled three times For countertop font in...

Страница 17: ...p Service Cold sensor Closed Internal fault Call Zip Service Flood sensor Open Internal fault Call Zip Service Condenser sensor Closed Internal fault Check Ventilation Call Zip Service Condenser senso...

Страница 18: ...ools down and reports that its internal temperature has returned to 40 C or lower UV Under Current Tried to dispense cold water and current of UV C Module not at minimum threshold a The 12V external p...

Страница 19: ...help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details End of life disposal In Australia Zip offers a full...

Страница 20: ...efer to User Guide for operation and maintenance ZipWater Australia PtyLtd ABN46000578727 67 77AllinghamStreet CondellParkNSW2200 Postal LockedBag80 Bankstown1885 Australia Tel 612 97963100 Freecall18...

Отзывы: