18
805812 v1.05 06.20 HydroChill Install Instructions
Installation instructions
2.4 Connect mains water and filter
All fittings are supplied with the appliance kit. As the installer, it is your
responsibility to supply and install any additional valves as required by
local regulations and relevant standards.
When cutting tubes, make a clean cut straight across the tube. Do not
lengthen tubes beyond the maximum supplied length.
Ensure the electrical power is off and the power cord is unplugged.
Fit the pressure limiting valve, non-return valve and adapter to the
mains water inlet, according to the diagram.
Connect the blue 9.5mm (3/8") hose between mains water supply and
filter head.
Filter head
1. Choose a suitable location in the cupboard wall to mount the filter
head bracket, within reach of the hoses between the mains water
supply and the chiller water inlet. Allow clearance for the filter
cartridge to be easily fitted and removed.
2. Mount the filter head bracket in an upright position, using the
screws supplied.
3. Fit straight or elbow connectors (supplied) to the filter head inlet
and outlet, as required for routing the hose. Measure and trim the
blue hose to connect the water supply to the filter inlet.
4. Unpack the filter cartridge and remove the sanitary cap. Avoid
touching the filter O-rings or filter opening as this may cause
bacterial contamination of the cartridge.
5. Write today’s date where shown on the label.
6. Slightly moisten the O-rings with regular tap water and align the
front cartridge label to the left.
7. Gently but firmly push the cartridge up into the filter head and
turn to the right, as far as it will go without forcing it. The cartridge
should now be locked in position, with the front label facing
forward.
8. The new filter should be flushed before use. Connect a hose to
the filter outlet and place the open end of the hose into a bucket
or container. Turn on the water supply and flush approximately 10
L through the filter. At this point you can fill the bath of the unit
while flushing the filter.
9. Turn off the water supply. Wipe up any spills and dispose of the
used cartridge and packaging thoughtfully.
2.5 Connect mains water and chiller
Install a T-off fitting in the hose from the filter outlet, for ambient
water to tap (between filter and chiller). Connect one hose to an
appropriate fitting at the inlet at the front of the chiller, marked “IN
H2O”. The other hose will be connected to the tap for ambient water.
Mains water
isolation valve
(not supplied)
Pressure Limiting
Valve (PLV)
Non-return valve
1/2" to 3/8" adapter
Hose (to filter)
Stop valve
ROTATE
PULL DOWN
1
2
1
2
ROTATE
INSERT