Installation instructions & user manual
804545UK V2.03 Aug 2018 - Zip Hydroboil
Technical support
Tel: 0345 6 005 005 Email: [email protected] www.zipwater.co.uk
Before installation
Technical specification, page 5 for power ratings.
Note
Check cable and plumbing against inlet /outlet positions before proceeding.
•
A wholesome water supply connection with isolating valve within reach of the Hydroboil and positioned so
that the stop cock will not be obstructed when the Hydroboil is installed.
• Vent / outlet drainage to a draining board, drip tray or sink bowl area.
•
A wholesome cold water supply with a minimum working pressure of:
(see Technical specification, below min. / max. water supply pressure).
•
A 0.35 MPa (3.5 bar) pressure limiting valve supplied must be fitted if the incoming mains water pressure is
likely to exceed 0.5 MPa (5.0 bar).
•
The Hydroboil must be placed with its base in a horizontal position.
IMPORTANT!
Do not proceed with the installation if these requirements are not met.
Technical specification
Product
code
Tank
size
(litres)
Heat up
time
(Inlet
15°C)
Heat up
time
(Inlet
10°C)
Rated voltage and
power
Dimensions
(mm)
W x D x H
Filled
weight(Kg)
301552
1.5
10mins
11mins
220-240V, 50Hz, 1400W
289 x 180 x 335
10.0
303552
3.0
16mins
17mins
220-240V, 50Hz, 1400W
289 x 180 x 431
12.5
305552
5.0
16mins
17mins
220-240V, 50Hz, 2200W
318 x 198 x 465
16.5
307552
7.5
23mins
23mins
220-240V, 50Hz, 2200W
318 x 198 x 578
20.5
310552
10.0
38mins
40mins
220-240V, 50Hz, 2800W
390 x 244 x 600
29.5
315552
15.0
40mins
43mins
220-240V~, 50Hz, 2800W
390 x 299 x 600
34.5
325552
25.0
47mins
50mins
220-240V~, 50Hz, 2800W
390 x 299 x 780
47.0
340552
40.0
60mins
64mins
380-415V, 2N~, 50Hz, 5600W
515 x 284 x 840
71.0
Min / Max water supply pressure
Hydroboil.........................................0.07 MPa (0.7 bar) - 0.5 MPa (5.0 bar)
WARNING !
If the incoming mains water pressure is likely to exceed 0.5 MPa (5.0 bar), a 0.35 MPa
(3.5 bar) pressure limiting valve must be installed in the cold water supply line.
Note
Optional Water Block is recommended to be fitted in the water supply line to minimise the potential damage
in the event of leakage, call Zip on 0345 6 005 005.
!