Spare parts list  3 - 7.5 Litre models

Ref

Part number

Description

1

94443

HB 3Ltr Tank Assy

1

94444

HB 5Ltr Tank Assy

1

94445

HB 7.5Ltr Tank Assy

2

94750

Earth Wire

3

94758

Fascia HB UK

4

94448

Tap Lock Nut

5

SP90501

Tap Top Assy

6

93730

Flow Insert

7

Not available

8

SP90081

Thermostat

9

94752

Loom Ther-Overload

10

94753

Wire Brown 140mm 6.3QC x 1sqmm

11

Not available

12

94454

Cistern Tank

13

94755

Ball Valve Assy

14

94456

Cistern Gasket

15

94457

Cistern Lid

16

SP93118

Elbow Stem 1/4"

17

90100

Grommet, Cistern to Tank

18

94458

Overload 4 terminal, 2 pole, 90 deg

19 & 20

SP90494

Seal Transfer Tube & Metering Tube

21

SP90485

Element Assy 1500W 3Ltr

21

SP90486

Element Assy 2400W 5 & 7.5Ltr

22

94465

Bush Vent Assy 3Ltr

22

94466

Bush Vent Assy 5Ltr

22

94467

Bush Vent Assy 7.5Ltr

23

94757

UK Inlet Assy

24

94470

Tap Assy (inc: 5,6,7)

25

94473

Hot Tank Gasket Kit 3Ltr

25

94474

Hot Tank Gasket Kit 5&7.5Ltr

26

94759

Light Pilot series 2000 365 lg

27

94760

Lens, HB UK

 

Содержание Hydroboil 301552

Страница 1: ...03 Aug2018 ZipHydroboil Technicalsupport Tel 03456 005005 Email service zipindustries co uk www zipwater co uk Installationinstructions usermanual Zip Hydroboil Onwallboilingwater Modelnumber 301552...

Страница 2: ...onnections 9 Step 4 Assembly Assembly 10 Step 5 Commission the Hydroboil Earth continuity verification 11 Turn the mains power and water on 11 Trouble shooting Trouble shooting table 12 Operation Oper...

Страница 3: ...power supply In hard water areas mineral scale accumulation in the boiling chamber of the Zip Hydroboil may become a problem consideration should be given to the maintenance required A suitable form...

Страница 4: ...penses into the drip tray or sink bowl area and that the vent is plumbed to a safe location see page 8 Lifting Take care when lifting The Hydroboil may exceed safe lifting limits If you feel this is b...

Страница 5: ...f these requirements are not met Technical specification Product code Tank size litres Heat up time Inlet 15 C Heat up time Inlet 10 C Rated voltage and power Dimensions mm W x D x H Filled weight Kg...

Страница 6: ...sed only if essential for filling larger vessels Provide clearance for service access of not less than 150mm top 65 mm left 20mm right Mark corner positions for the Hydroboil on the wall in order to p...

Страница 7: ...3456 005005 Email service zipindustries co uk www zipwater co uk Installation instructions 10 litre models 15 40 litre models Strain relief bush cable gland Terminal block Escutcheon Tap nut Tap Escut...

Страница 8: ...ated from the mains water supply for servicing Water pressure requirements See Technical specification page 5 Venting The Hydroboil is an open vented water heater and as such it is essential to provid...

Страница 9: ...lief bush to secure the cable Concealed electrical connection Connect the concealed power cable through the rear access opening to the terminal block via the strain relief bush See diagrams above and...

Страница 10: ...for users of the Hydroboil Step 4 Assembly Refit the outer case and secure the 2 sets of screws top and bottom see page 6 to 7 Before installing the tap ensure enough P T F E thread tape is applied t...

Страница 11: ...the other test lead to a cover fixing screw then the tap Warning The water may be boiling Verify that in every instance the electrical resistance does not exceed 1 ohm Warning This appliance must be e...

Страница 12: ...om vent Power on but no heat Overload repeatedly tripping with excessive steam Overload repeatedly tripping without excessive steam Internal adjustment blocked vent vented incorrectly see page 8 Conta...

Страница 13: ...ng dimension 3 7 5 Litre models 37 1 5 3 0 L 198 52 5 0 7 5 L 38 1 5 3 0 L 52 5 0 7 5 L 19 395 3 0L 429 5 0L 542 7 5L 310 1 5L 37 76 273 1 5 3 0 L 302 5 0 7 5 L 56 COLD INLET BOILING WATER VENT 25 40...

Страница 14: ...ounting dimensions 10 40 litre models 295 10 25 L 39 5 573 15L 753 25L 813 40L 573 10L 41 84 374 10 25 L 499 40L 62 COLD INLET BOILING WATER VENT 25 41 Positioning pin 6 External plumbing Internal plu...

Страница 15: ...Ther Overload 10 94753 Wire Brown 140mm 6 3QC x 1sqmm 11 Not available 12 94454 Cistern Tank 13 94755 Ball Valve Assy 14 94456 Cistern Gasket 15 94457 Cistern Lid 16 SP93118 Elbow Stem 1 4 17 90100 G...

Страница 16: ...l 804545UK V2 03Aug2018 ZipHydroboil Technicalsupport Tel 03456005005 Email service zipindustries co uk www zipwater co uk Spare parts diagram 3 7 5 litre models 1 4 6 7 5 2 10 8 23 22 9 19 17 18 15 1...

Страница 17: ...ap Top Assy 6 93730 Flow Insert 7 Not available 8 SP90081 Thermostat 9 94447 Kit Escutcheon 10 94758 Fascia HB 11 94470 Tap Assy inc 5 6 7 12 94454 Cistern Tank 13 94755 Ball Valve Assy 14 94456 Ciste...

Страница 18: ...18 Installationinstructions usermanual 804545UK V2 03Aug2018 ZipHydroboil Technicalsupport Tel 03456005005 Email service zipindustries co uk www zipwater co uk Spare parts diagram 10 40 litre models...

Страница 19: ...f separately to any other household waste Within each of the European Union member countries provisions have been made for collection and recycling of unwanted electrical and electronic equipment In o...

Страница 20: ...anual 804545UK V2 03Aug2018 ZipHydroboil Technicalsupport Tel 03456005005 Email service zipindustries co uk www zipwater co uk ZipWaterUK 14BertieWardWay Dereham Norfolk NR191TE 03456005005sales zipin...

Отзывы: