background image

Page 3 of 12 

Zip CH103, CH104 - Installation & operating instructions - 82127UK - June 2015 v1.04

Safety information 

continued

Concealed filtered water chiller with heavy duty lever action tap.

Delivers 140 glasses per hour of chilled filtered water within the operating range 
of 5ºC to 10ºC.

15mm compression fitting connecting to mains water supply.

A potable water supply is required with minimum water pressure of 0.17 MPa (1.7 
bar). If the incoming mains cold water supply pressure exceeds 0.7 MPa (7.0 
bar) a pressure reducing valve is required to be fitted in the supply line. (See 
Spare parts and accessories below).

Power Supply: 1/N/PE 230 V AC.

Power Rating: 450 W.

Chiller type: Fan cooled condenser with compressor.

Storage capacity: 1.8 Litres.

Refrigerant type: Non-toxic R134A.

Heavy duty ChillTap

®

, chrome plated brass, self return lever action, vented with 

swivel head.

Filtration type: Submicron filtration.

Chiller unit dimensions: Height: 385mm, Width: 355mm, Depth: 290.

Weight: Full 24Kg,  Empty 22.2Kg

Technical data

Spare parts and accessories

Spare parts
Part No. Description

SP99249

Heavy duty ChillTap

®

ZT502

Sub micron filter

Optional accessories
Part No. Description

HE45004** Water block (water shut down system)

ZI001

Bubbler, non-vented system kit

AQ3 

Pressure reducer set at 0.35 MPa (3.5 
bar)

This appliance must not be used by any person (including children) with limited 
physical, sensorial or mental abilities or failing experience and / or knowledge 
unless they are supervised by a person responsible for their safety, or received 
instructions about how to use the appliance.
Children should be supervised in order to make sure that they do not play with 
the appliance. 
The appliance must only be used when correctly functioning and installed.
This product is approved to the LVD and EMC directives and is CE marked.
This product has been examined, tested and found, when correctly 
fitted, to comply with the requirements of the United Kingdom Water 
Regulations / Byelaws (Scotland).  
The products are listed under the WRAS (Water Regulations Advisory Scheme) 
Water Fittings and Materials Directory.

Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure 

to observe these instructions.

Leave these instructions with the end user after installation.

Содержание Chilltap CH103

Страница 1: ...ions 82127UK June 2015 v1 04 Installation and operating instructions Zip ChillTap and Wall Fountain Under counter chiller and wall recessed chilled water systems Affix model number label here Model CH...

Страница 2: ...be carried out by a competent installer who will then be responsible for adhering to all relevant standards and regulations Appliance to be wired to a double pole switched fused spur with a minimum br...

Страница 3: ...ssories Spare parts Part No Description SP99249 Heavy duty ChillTap ZT502 Sub micron filter Optional accessories Part No Description HE45004 Water block water shut down system ZI001 Bubbler non vented...

Страница 4: ...ic tubing to prevent it from kinking or crushing around a bend The plastic tubing contains water under mains pressure be careful not to nick scratch or damage it during installation Cut the tube squar...

Страница 5: ...ming water supply line Note Before assembling the compression fitting to the valve apply sufficient PTFE tape to the thread to ensure a water tight connection Do not turn the water on until the comple...

Страница 6: ...pes should not be overly long but must allow sufficient length to avoid stress at connection points CH103 ChillTap installation instructions continued Connect the blue tube from the tap to the push fi...

Страница 7: ...the bottom of the unit Check that there is enough free space within the wall to allow for completely recessing the Wall Fountain The top half recesses 270mm and the bottom half requires a depth of 350...

Страница 8: ...the sink bowl to an appropriate waste in accordance with local by laws Keep the drainage piping clear of the chiller space approx 380mm above the base tray Connect to water supply Install an isolatio...

Страница 9: ...anging the filter For safe operation the filter cartridge should be replaced at least every 6 12 months or earlier if you notice a persistent reduction in water pressure from the tap or an unpleasant...

Страница 10: ...for service check that both the water and electricity supplies are turned on and functional Call Zip a qualified electrician or plumber for assistance service spare parts or enquiries Zip customer se...

Страница 11: ...mption Zip does not exclude restrict or modify any liability that cannot be excluded restricted or modified or which cannot except to a limited extent be excluded restricted or modified as between the...

Страница 12: ...orfolk NR19 1TE www zipheaters co uk Telephone 0845 6 005 005 0345 6 005 005 Fax 01362 692448 Web www zipheaters co uk e mail info zipheaters co uk Registering Your Purchase Registering your Zip insta...

Отзывы: