background image

10

10.1 Installing the product

 

Insert the straight pin into the designated fit on the product.

3
4

 

Position the product on the robot using the straight pin.

 

Mount the product on the robot with the mounting screws.
•  To tighten the mounting screws, there are threaded holes on the 

underside of the product.

 

Align the axis compensation module centrically.

3

Straight pin (not included in the scope of delivery)

4

Mounting screw

10.2 Installing the energy supply

NOTICE

 

You can find the information in the technical data sheet on our website.

 

Close off unused connections using suitable dummy plugs.

 

The authorized connections that are available can be found in the accessories list on our website. The 

necessary ordering information can also be found there.

 

Use compressed air in accordance with DIN ISO 8573-1 [4:4:4].

 

Insert the screw fitting into a pneumatic 

connection designated for this purpose.

6

5

5

Pneumatic connection

6

Push-fit fitting

INSTALLATION AND OPERATING INSTRUCTIONS: 

ZR1000-A

DDOC01702 / -

EN / 2022-09-27

Zimmer GmbH • Im Salmenkopf 5 • 

 77866 Rheinau, Germany • 

 +49 7844 9138 0 • www.zimmer-group.com

Содержание ZR1000-A Series

Страница 1: ...INSTALLATION AND OPERATING INSTRUCTIONS Axis compensation module pneumatic ZR1000 A series DDOC01702 THE KNOW HOW FACTORY www zimmer group com...

Страница 2: ......

Страница 3: ...y notices 5 3 Proper use 6 4 Personnel qualification 6 5 Product description 6 5 1 Forces and torques 6 5 2 Type plate 6 6 Functional description 7 7 Technical data 7 8 Accessories scope of delivery 7...

Страница 4: ...ding these dangers The warning symbols are assigned according to the type of danger WARNING This notice warns of a situation that is potentially hazardous to personal health Ignoring these notices can...

Страница 5: ...permission of the manufacturer Use of the product under extreme conditions such as aggressive fluids or abrasive dusts Additional drilled holes or threads Zimmer GmbH shall accept no liability for an...

Страница 6: ...f 8 bar The product is designated for use in closed facilities Direct contact with perishable goods food is not permitted 4 Personnel qualification Installation commissioning and maintenance may only...

Страница 7: ...FORMATION You can find the information in the technical data sheet on our website This data varies within the series depending on the specific design Please contact Zimmer Customer Service if you have...

Страница 8: ...Keep the storage location as dust free and dry as possible Avoid temperature fluctuations observe and adhere to the temperature range Avoid wind drafts water condensation formation Cover the product w...

Страница 9: ...llation may only be carried out by qualified personnel in accordance with these installation and operating instructions Switch off the power supply before any assembly installation or maintenance work...

Страница 10: ...supply NOTICE You can find the information in the technical data sheet on our website Close off unused connections using suitable dummy plugs The authorized connections that are available can be found...

Страница 11: ...nsors The sensor is used for magnetic piston position sensing 7 8 9 Install the sensor holder on the product using the mounting screw 7 Sensor holder 8 Mounting screw 9 Sensor INFORMATION More informa...

Страница 12: ...product is maintenance free as mentioned above perform a regular visual inspection to check for any corrosion damage or contamination Have maintenance work be performed by Zimmer Customer Service whe...

Страница 13: ...he specific technical documents were produced in accordance with Annex VII Part B of this Directive We undertake to provide the market supervisory bodies with electronic versions of special documents...