11.3 Sensing positions for the SB series
NOTICE
The cables that are used by Zimmer GmbH feature a minimum bending radius of 10 x the outer diameter.
This bending radius must not be undershot!
►
Freely suspended cables must be secured to prevent excessive motion loads or pinching.
►
The contacts of the energy supply must be dry, clean and undamaged at all times.
Ö
Damage to the contacts can result in malfunction of the product.
The figure provides an example of the positioning of sensors for a swivel angle of 180°.
►
Insert the sensor into the protective sleeve.
co
cn
cm
cl
►
Position the sensor in the desired sensor
hole.
►
Securely clamp the sensor using the
corresponding grub screw.
►
Close unneeded sensor holes using straight
pins.
cl
Set Screw
cm
Sensor position for swivel angle 90°
cn
Protective sleeve
co
Sensor
INFORMATION
Inductive sensors are available in the following versions:
• 5 m cable with exposed lead
• 0.3 m cable with plug
• 0.3 m cable with direct plug orientation
►
Please note that the cable can be shortened or fabricated with plugs in sizes M8 and M12.