INSTALLATION AND OPERATING INSTRUCTIONS:
Motor spindle, HF150-003 series
25
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
EN / 2020-10-22
DDOC00746 / -
10.3 Tool interface (setting dimensions/clamping force)
DANGER:
Risk of fatal injury due to ejection out of the tool holder during operation of the motor spindle!
Ö
In the event that the motor spindle clamping system was incorrectly set, a loss/ejection of the tool cannot be
ruled out during operation (rotation).
Ö
Injury to personnel or material damage may result.
Risk of fatal injury due to insufficient clamping force of the tool holder of the motor spindle!
Ö
If the clamping force of the motor spindle is insufficient (“10.3.1 Checking the clamping force”), a loss/
ejection of the tool cannot be ruled out during operation (rotation).
Ö
Injury to personnel or material damage may result.
NOTICE:
Do not use compressed air to clean the tool interface!
Do not use any cleaning agents that contain solvents!
Verify the setting dimensions at the tool interface.
When doing so, the following work steps must be observed:
►
Switch the machine to “setup mode.”
►
Secure the tool to prevent it from falling.
►
Actuate the loosening unit using the machine control system to release the tool.
►
Remove the tool or unit from the motor spindle in the axial direction.
►
Clean the motor spindle using a clean, soft rag.
• Plane face of the tool holder
•
Gap between the quick-change tool adapter and the surface of the taper
►
To extend the clamping set, actuate the loosening unit by using the machine control system
Ö
The clamping system is unclamped/extended if: Nominal dimension
X
= 10.5 +0.1 mm
►
Bleed the clamping system by using the machine control system.
Ö
The clamping system is retracted, “clamped without a tool” if: Nominal dimension
X
= 1.5 +0.1 mm
Nominal dimension X retr
ac
ted
Nominal dimension X ex
tended
►
Check the two positions of the clamping system to determine whether they are situated within the specified tolerance.
Ö
If the actual dimensions are NOT within the nominal dimensional tolerance, the motor spindle must not be operated!
In order to establish the correct setting dimensions, observe the installation instructions of the clamping set!
If it is ensured that the setting values correspond to the specifications, the following steps must be carried out:
►
Insert the tool or unit into the motor spindle in the axial direction.
►
Clamp the tool or unit by using the machine control system.
►
Check that the tool or unit fits correctly.
Ö
If an error message appears, repeat this process.
Ö
See table “Troubleshooting”.