DDOC00188
enu / 2016-08-31 / Index a
INSTALLATION AND OPERATING INSTRUCTIONS:
Pneumatic GSI series O-Ring gripper
Zimmer GmbH
●
Im Salmenkopf 5
●
77866 Rheinau, Germany
●
Phone: + 49 7844 9138-0
●
Fax: + 49 7844 9138-80
●
www.zimmer-group.de
Pneumatic fitting
Straight fitting
GV series
Order No.:
GVM5
plug-in connector
Angle, cable 5 m
M8 female connector
Order No.:
KAW500
Pneumatic fitting
Angle fastener
WV series
Order No.:
WVM5
plug-in connector
Straight, cable 5 m
M8 female connector
Order No.:
KAG500
Magnetic field sensor
MFS series
Angle, cable 5m
Order No.:
MFS103KHC
plug-in connector
Straight, field-attachable
Insulation displacement
connection
Series S, M8 connector
Order No.:
S8-G-3
Magnetic field sensor
MFS series
Angle, cable 0.3 m
M8 connector
Order No.:
MFS103SKHC
plug-in connector
Straight, field-attachable
Insulation displacement con-
nection
Series S, M12 connector
Order No.:
S12-G-3
8.
Maintenance
9.
Accessories
12
If the following points are observed, the gripper is maintenance-free for
5 million
gripping cycles.
• Driven with compressed air in accordance with ISO 8573.1 with the following parameters: - Solid content class 2
-
Moisture
content
class
4
-
Oil
content:
Class
1
(unoiled
air)
• Clean environment
• Use in accordance with performance data
• Ambient temperature not over 60°C for long periods
If the requirements are not adhered to, the maintenance interval will be reduced according to the application case.
NOTE:
We recommend using the Zimmer GmbH repair service for maintenance and the replacement of seals.
Dismantling and reassembling the gripper without authorization may result in complications as in some cases
special installation equipment is required.
CAUTION!
When dismantling a gripper with integrated springs (recognizable by the
spring symbol on the housing), use
an apparatus that prevents the piston or piston cover from being expelled by the pre-tensioned springs.
►
Risk of injury
►
Disassembly must be carried out by Zimmer service personnel only!