APPENDIX A CONTROLLER PRODUCT SPECIFICATIONS
I.
Specifications
Mode of Operation: ........................................................Intermittent. Duty Cycle: 10 seconds ON 30 seconds OFF
Input: ..........................................................................................................................100-240VAC, 50-60Hz, 700VA
Dimensions: ............................................................................ 5.2”(H) x 13.8”(W) x 17.5”(D) (13.2 x 34.9 x 44.5 cm)
Packaged Weight: ............................................................................................................................... 25 lbs (11.4kg)
Max Output (Ablate): ..........................................................................................400W
±20%
, 225 kHz, 175
Ω load
Max Output (Coag): ............................................................................................90W
±20%
, 225 kHz, 175
Ω load
Fuses: .................................................... 5x20mm Type “T” 6.3A /250V slow blow (Qty. 2; Littelfuse or equivalent)
Weight and dimensions indicated are approximate. Specifications are subject to change without notice.
II.
Protection
Class 1, Type BF, intermittent operation; Enclosure IP 21
III.
Operating Conditions
Temperature: ....................................................................................................................................... 10°C to 40°C
Relative Humidity: ........................................................................................................ 30% to 75% non-condensing
Atmospheric Pressure:..................................................................................... 878 to 1082 cmH
2
O (86 to 106 kPa)
IV.
Transport and Storage Requirements
Temperature: ....................................................................................................................................... -18°C to 60°C
Relative Humidity: ........................................................................................................15% to 85% non-condensing
Atmospheric Pressure:..................................................................................... 510 to 1082 cmH
2
O (50 to 106 kPa)
APPENDIX B OPTIONAL DATA OUTPUT
The Tricera Controller can be used with the ZEOS video system. This integration allows for an onscreen dashboard display that
allows system settings and modes to be displayed on the endoscopy monitor. The ZEOS System can be set up by connecting
the ZEOS console to the rear of the Tricera Controller via the USB port (Fig. 2, item 12). The image below shows the ZEOS
video system displaying data to the operating monitor.
APPENDIX C ABBREVIATIONS
Controller
Tricera Controller
LED
Light Emitting Diode
RF
Radiofrequency
LCD
Liquid Crystal Display
APPENDIX D TONES
•
Tone 1 – Treatment Tone ABLATE
•
Tone 2 – Treatment Tone COAG
•
Tone 3 – Connect Tone
•
Tone 4 - Disconnect Tone
•
Tone 5 – Lockdown Error Tone
•
Tone 6 – Recoverable Error Tone