Exhaust air fan Aero_aH 100 with integrated room and cellar dehumidification control
 

 

 

1019-1-0002

 

Handbuch 31.01.2021_JUSC_Aero_aH100| 

14 

 

3.

 

Product description 

The 

Aero_aH  100

  is  a  small  room  fan  for 

dehumidifying  rooms,  especially  cellars,  and  similar 
adjoining rooms. The device has a fixed indoor grille 
and  is  equipped  with  an  integrated  indoor  sensor. 
Controlled  dehumidification  is  achieved  by  a 
comparison of the indoor and outdoor climate. This 
requires the closing flap AP 100 with built-in outdoor 
climate  sensor  to  be  connected.  To  support  room 
dehumidification,  a  ventilation  fan  can  also  be 
controlled directly via the Aero_aH 100. 

4.

 

Product features 

4.1.

 

Dehumidification control 

Efficient dehumidification of rooms with controlled 
ventilation  involves  removing  moist  air  from  the 
room while simultaneously supplying dry air.  

For  this  purpose,  the  absolute  humidity  (aH)  is 
determined  as  a  measure  of  the  water  vapour 
content  in  the  air  by  means  of  the  two  climate 
sensors (indoor and outdoor sensor). 

Measurements  are  taken  immediately  after  the 
device  has  been  switched  on.  As  soon  as  the 
absolute  outdoor  humidity  is  lower  than  the 
absolute  indoor  humidity  (aHoutside  <  aHinside), 
the  fan  of  the  Aero_aH  100  is  automatically 
switched  on  and  a  dehumidification  period  begins 
(active time). 

Ventilation  and  dehumidification  take  place 
approximately  every  10  minutes.  Afterwards,  the 
fan is switched off for another 10 minutes so that 
the moisture-loaded room air can mix with the drier 
outdoor  air  supplied  (passive  time).  After  this 
passive period, the climate comparison is repeated. 

If the absolute humidity of the outdoor air is higher 
than  that  of  the  indoor  air  during  a  climate 
comparison  (aHoutdoors  >  aHindoors),  no  air 
exchange will be carried out. This prevents moist air 
from flowing in. The fan is only switched on again 
when the climate 

 

Button 1 

Reference value 
determination 

Button 2 

Manual ventilation 

LED 1 

Operating mode 

LED 2 

Fan status 

 

Display 

Function 

LED 1: On 

Automatic operating 
mode  

LED 1: Flashing 

Manual ventilation 

LED 1: Flashes 
twice with long 
pause 

Frost protection 

LED 1: Flashes 
three times with 
long pause 

Dry protection 

LED 2: On 

Active time during 
dehumidification 
(Fan on) 

LED 2: Off 

Passive time during 
dehumidification 
(Fan off) 

LED 2: Flashing* 

Successful 
dehumidification 
achieved (resettable 
with button 1) 

 

 

Содержание Aero aH 100

Страница 1: ...feuchtung Mounting and operating instructions Exhaust air fan with integrated automatic room and cellar dehumidification control Notice de montage et mode d emploi D shumidification automatique des pi...

Страница 2: ...imate sensor D tecteur d atmosph re int rieure 6 Elektronikabdeckung Electronics cover Cache lectronique 7 Elektronikplatine Electronic circuit board Platine lectronique 8 Innengitter Inner grille Gri...

Страница 3: ...1 Lieferumfang Ventilatoreinheit mit Innensensor Au enklappe mit Au ensensor Sensorverbindungskabel Schaumstoffb nder Montage und Betriebsanleitung 2 Allgemeine Hinweise Lesen Sie diese Montageanleit...

Страница 4: ...t sofort nach dem Einschalten des Ger tes Sobald die absolute Au enfeuchte geringer ist als die absolute Innenfeuchte aHau en aHinnen wird der Ventilator des Aero_aH 100 automatisch eingeschaltet und...

Страница 5: ...Optional kann der manuelle Betrieb mit einem externen Taster erfolgen siehe Schaltbild in Kapitel 13 Ein manuelles Ausschalten des Ventilators w hrend der Betriebsart Automatik durch den Taster ist n...

Страница 6: ...irken ACHTUNG Sch digung der Bausubstanz durch manuelles L ften Ein zu langes manuelles L ften kann bei feuchten Au enbedingungen zu einer Raumbefeuchtung f hren Daher ist unbedingt bei Verwendung ein...

Страница 7: ...r d rfen nicht mit dem Ger t spielen Zuluftnachstr mung innerhalb der Wohnung Die Luftf hrung in der Wohnung muss so erfolgen dass m glichst keine Luft aus K che Bad und WC in die R ume in denen der A...

Страница 8: ...orkabel nicht vom Sensor l sen es wird durch das Rohr mit dem Ventilator w hrend des Geh useeinbaus verbunden 2 Beigef gtes Schaumstoffband am Stutzen mittig anbringen 6 5 Ventilator 1 Ger t auspacken...

Страница 9: ...er Steuerelektronik werden maximal 10 cm im Ventilatorgeh use ben tigt 7 3 Geh useeinbau Ventilator 1 Geh use 1 in Wanddurchbruch Wand h lse stecken TOP oben 2 Geh use waagerecht ausrichten und die be...

Страница 10: ...gung bei Kurzschluss Schutzleiter und nicht ben tigte Adern isolieren 1 Im Ger t nur Einzeladern verlegen Dazu Mantel der Netzleitung auf einer L nge von 70 mm entfernen Einzelne Adern auf 9 bis 10 mm...

Страница 11: ...ung ausschalten ACHTUNG Ger tebesch digung bei falschem Reinigungsmittel Abdeckung 4 und Design abdeckung 3 nur mit Wasser reinigen Keine aggressiven Reinigungsmittel verwenden 1 Innenteile des Ventil...

Страница 12: ...halten 1 Abdeckungen entriegeln Pfeil und abnehmen 2 Elektronikabdeckung 6 entfernen 3 Rastnasen 3 Netzleitung entfernen Ventilator ausbauen 12 Entsorgung Nicht in den Restm ll werfen Das Ger t enth l...

Страница 13: ...ing 21 10 TroubleshootingFehler Textmarke nicht definiert 11 Disassembly 22 12 Disposal 22 13 Wiring diagram 22 14 Support 22 1 Scope of delivery Fan unit with indoor sensor Outer flap with outdoor se...

Страница 14: ...been switched on As soon as the absolute outdoor humidity is lower than the absolute indoor humidity aHoutside aHinside the fan of the Aero_aH 100 is automatically switched on and a dehumidification p...

Страница 15: ...rried out with an external button see wiring diagram in chapter 13 It is not possible to switch off the fan manually with the button during automatic mode Manual ventilation is also possible during fr...

Страница 16: ...fabric if ventilated manually Excessive manual ventilation can lead to room humidification when the outdoor humidity is high Therefore it is essential to pay attention to the duration of ventilation w...

Страница 17: ...as far as possible no air from the kitchen bathroom and lavatory can flow over into other rooms where the Aero_aH 100 is installed A room to be vented must be equipped with an unclosable open supply a...

Страница 18: ...over unlock the catch arrow with a screwdriver 2 Remove the indoor climate sensor 5 3 Remove the electronics cover 6 Unlock the catch arrow with a screwdriver 4 Attach the supplied foam tape to the ce...

Страница 19: ...es arrows 3 Remove the housing 1 drill M6 dowel holes 6 mm and insert the dowels 4 Carefully push the cable grommet 9 out of the enclosure and remove it ATTENTION Risk of short circuit and damage to t...

Страница 20: ...for a length of 70 mm Strip the insulation of individual wires to 9 to 10 mm 2 Connect the mains cable to the spring terminal 13 according to the wiring diagram 14 see also wiring diagram in chapter 1...

Страница 21: ...used Clean cover 4 and design cover 3 with water only Do not use aggressive cleaning agents 1 Clean the inner parts of the fan with a dry cloth only 2 If the design cover 3 is very dirty carefully rem...

Страница 22: ...w and remove them 2 Remove the electronics cover 6 3 catches 3 Remove the mains cable and the fan 12 Disposal Do not dispose of the product in the residual waste The unit partly contains recyclable ma...

Страница 23: ...mode d emploi fournis 2 Remarques g n rales Lisez attentivement la pr sente notice de montage avant d utiliser l Aero_aH100 Suivez les instructions Conservez cette notice de montage pour une utilisati...

Страница 24: ...air ext rieur sec qui entre p riode passive Une fois la p riode d attente coul e la comparaison entre humidit int rieure et ext rieure reprend Si la comparaison de la teneur en humidit d termine que...

Страница 25: ...externe interrupteur En remplacement du bouton 2 le mode manuel peut galement tre command par un bouton externe ou interrupteur voir le sch ma de branchement au chapitre 14 Ceci est assur par une rec...

Страница 26: ...appareil dans des installations individuelles d extraction d air conformes la norme DIN 18017 3 proximit de mat riaux liquides ou gaz inflammables pour l acheminement de produits chimiques de gaz ou d...

Страница 27: ...tiquer un per age de cloison ou percer un avant trou diam tre minimal 105 mm 3 Poser le c ble secteur montage encastr jusqu au site de montage pour les carts respecter voir plus haut Ce faisant faire...

Страница 28: ...r les crochets d arr t fl che avec un tournevis 4 Poser le ruban isolant fourni au centre de la tubulure Sur le mod le Aero_aH100 poser imp rativement le ruban isolant pour que les appareils n aspiren...

Страница 29: ...4 Pousser avec pr caution le manchon de c ble 9 hors du bo tier et le sortir ATTENTION Risque de court circuit et d endommagement de l appareil Risque de p n tration d eau en cas d insertion incorrec...

Страница 30: ...individuels sur 9 10 mm 2 Brancher lectriquement le c ble secteur sur la borne ressorts 13 conform ment au sch ma de branchement 14 voir aussi le sch ma de branchement 3 Contr ler l assise du manchon...

Страница 31: ...duits de nettoyage agressifs 1 Nettoyer les pi ces int rieures du ventilateur uniquement avec un chiffon sec 2 Si le cache de protection design 3 est tr s sale le d poser avec pr caution et le nettoye...

Страница 32: ...on fl che et les d poser 2 Retirer le cache lectronique 6 3 ergots d encliquetage 3 Retirer le c ble secteur Ventilator ausbauen 4 D monter le ventilateur 11 limination Ne pas liminer avec les ordures...

Отзывы: