All information contained herein is the exclusive copyright of Round Bank Engineering Ltd and is not to by copied,
duplicated or otherwise distributed without the express permission of Round Bank Engineering Ltd, Unit 7, Victoria
Business Park, Halifax, UK, HX1 5ND - +44 (0) 1422 647177
–
Order based on Design Document
7-0112-A
PID Delay (ms)
If the PID is enabled, the motor will typically startup as normal without the PID. Meaning, that the
motor start with a duty cycle set with the Min duty cycle parameter, then it will accelerate up
towards the Fixed Speed (%duty) parameter. Once the motor speed exceeds the Min Frequency (Hz)
parameter, the motor will stop accelerating, delay for the PID Delay (ms) time, enable the PID then
accelerate up at the PID Acc/Dec rate until the Fixed Speed (PID Hz) is reached.
This parameter is only used when the PID is enabled.
PID Enabled
A value of 0 = PID disabled, a value of 1 = PID is Enabled.
Changing this value when the motor is running will have no effect. The motor will need to be
stopped to enable or disable the PID.
PID Data Items
Data Item Number
Details
0
PID Enabled
–
0 = No, 1 = Yes
1
PID Demand Frequency
2
Actual Motor Frequency
3
Frequency Error
4
Proportional Term
5
Integral Sum Low
6
Integral Sum High
7
Integral Term Low
8
Integral Term High
9
PID Output
Output Setting
A settable output value that can be changed depending on what the requirements are:
Output 1 Value
Condition
0
Always off (low)
1
High on Fault
2
High on commutation
3
High every electric Frequency
4
Motor running