background image

ZIKA

 

 

I- TIG 200AC/DC II WELDING MACHINE 

 

USER MANUAL

 

 

Содержание I-TIG 200AC/DC II

Страница 1: ...ZIKA I TIG 200AC DC II WELDING MACHINE USER MANUAL...

Страница 2: ...may cause hurt or property lose if it is not followed The words after this sign means there is potential risk which may cause equipment fault or break if it is not followed Version Version YF 01A A0 R...

Страница 3: ...CAL PARAMETERS TABLE 10 PANEL FUNCTION INSTRUCTION 11 INSTALLATION INSTRUCTION 12 MAINTENANCE 16 NOTES BEFORE CHECKING 16 NOTES OR PREVENTIVE MEASURES 17 QUESTIONS TO BE RUN INTO DURING WELDING 18 TRO...

Страница 4: ...cause choke Spark and hot workpiece after welding may cause fire Bad connected cable may cause fire Incompletion connection of workpiece side circuit may cause fire Never weld on the case of tinder st...

Страница 5: ...electric shock Keep away from any electric parts Earth the machine and workpiece by professional personnel Cut off the power before installation or checking and restart 5 minutes later The capacitance...

Страница 6: ...t the supervisor s inspection when operating in narrow space Air the room and wear breathe preventive facilities Never operate in degrease washing or spray space Using breathe preventive facilities wh...

Страница 7: ...switch following For better work efficiency and power source maintenance please note the Precautions against toppling over Never use the welding equipment for pipe thawing Lift the power source from s...

Страница 8: ...eed extra preventive measures h Practical state of the welding and other activities Users should observe the following dos and don ts to decrease radiation interference a Connect the welding equipment...

Страница 9: ...at DC function can be used to weld stainless steel alloyed steel carbon steel copper and other color metals and AC function can be used to weld aluminum and aluminum alloy materials such as welding of...

Страница 10: ...ated output voltage V TIG 18 MMA 28 AC duty cycle 20 80 Pulse duty cycle 10 90 Post flow time S 0 10 Pulse frequency Hz 0 5 5 0 Basic value current A 5 200 Arc initiation current A 5 200 Attenuation t...

Страница 11: ...4 ARC start current adjustment 15 Positive output terminal 5 Welding current adjustment 16 Remoter control 6 Basic current adjustment 17 Torch switch socket 7 Down slope adjustment 18 Gas connector 8...

Страница 12: ...nal at the front panel fasten it clockwise and the earth clamp at the other terminal clamps the work piece 4 Correctly connect the arc torch or holder according to the sketch When use MMA welding Make...

Страница 13: ...am TIG Power supply 1Phase 220V Argon gas cylinder Connected to the ground Earth clamp Work piece TIG torch Installation diagram MMA Power supply 1Phase 220V Connected to the ground Earth clamp Electr...

Страница 14: ...o adjust arc initiation current and attenuation time 9 According to thickness set suitable welding current and basic value current When pulse switch is down position no basic value current 10 Press to...

Страница 15: ...o is 80 and at 5 position ratio is 20 Turn towards clockwise up side current gets short down side current gets long When turn counter clockwise it is opposite 3 Operating as the10 12 step above Notice...

Страница 16: ...scale and loose are found please give a good polish to them then connect them again tightly 4 Avoid water and steam enter into inner machine if them enter into machine please dry inner machine then c...

Страница 17: ...er should make sure the working area is adequately ventilated It is important for the performance and the longevity of the machine 2 Do not over load The operator should remember to watch the max duty...

Страница 18: ...r gas is not pure can lower welding quality 5 If air is flowing powerfully in welding environment that can lower welding quality B Arc striking is difficult and easy to pause 1 Make sure quality of tu...

Страница 19: ...or 2 3 min and restart it 5 24V relay of main return circuit on power board is not closed or damaged check 24V power and relay Replace it with same model series if it s damaged Fan is working abnormal...

Страница 20: ...S board close to insert of fan VH 07 then restart the machine 1 If abnormal indicator is still on turn off machine and disconnect power supply plug of HF arc striking power source close to insert of f...

Отзывы: