41
Front panel
LCD
DC input voltage/ DC input current/ DC input power/ AC output voltage/ AC output current/
AC output frequency/ AC output current/ AC energy performance/ Interior Temperature
/Heat dissipater temperature /Status message/Error message
Red
Earth failure or DC input insulation failure
LED
Yellow
The grid specifications do not coincide with the standard PV Inverter input
Green
The power of the solar cell is greater or lower than 5% of the PV Inverter output power
Keyboard
UP KEY/DOWN key/LEFT key/RIGHT key/ INTRO key
Protection
Network
Over/Undervoltage, Over/underfrequency, Earth failure, DC insulation failure, Island
Short-circuit
DC input: Input diode/Electronic circuit
AC output: Output relay/Electronic circuit
Overtemperature
≥
60°C (140°F) system will stop
Mechanical data
Height x Width x Depth
665 x 480 x 220
Weight
39kg
Protection class
IP 54
Refrigeration
Optimised refrigeration
AC connection
Connector
DC connection
Multi-contact type
Certification
Safety
VDE 4105, EN 62109-1, EN 62109-2, IEC 60146, G83/1-1, G59/2, IEC 62116, UL 1741
(1)
,
CEI 0-21
EMI/EMC
EN 61000-6-2, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3, IEEE 1547
Marks
VDE, CE, ENEL
* The inverter will limit power at high operating temperatures.
(1)
Manufactured under UL1741
Note:
The technical specifications may be modified without warning
For any other technical requirement or modification of existing characteristics please consult ZIGOR.