INSTRUCTION MANUAL
Semi-automatic BOV Filling Machine Z-2323
A0310.02.2323.905.1.EN
Page 21/39
Fig. 11. Adjusting product dose
Enable compressed air supply by moving the slide valve up to opened position.
Open the inflow of the product to the product cylinder by unscrewing the knurled screw
and gently tighten the securing nut on check-valve.
Conduct 5 trial cycles of filling, checking the precision of dosing by weighting or by volume
control.
If necessary, adjust the amount of dosed product.