INSTRUCTION MANUAL
Semi-automatic BOV Filling Machine Z-2323
A0310.02.2323.905.1.EN
Page 18/39
4.
Drain tank, in its lower part, is equipped with manual drain valve which allows the tank to
be emptied from gathered liquid. Tank needs to be emptied when amount of liquid will
reach ¾ of the tank volume. Exceeding that amount of liquid in the tank may lead to vacuum
generation system malfunction or blockage. CAUTION! Before returning to work, close the
drain valve!
Fig. 7. Drain tank with drain valve
Stopping the machine. Emergency Stop
Stopping of a Z-2323 takes place in a manner analogous to the run – you need to switch the manual
cut-off valve to closed position.
Additionally, the device was equipped with emergency stop button [Fig. 3, pos. 5], causing an
immediate lift of working heads in case of emergency. In order to return for work, release the
E-STOP button by pulling it out and press RESET button.
Drain valve lever
Содержание Z-2323
Страница 42: ...PNEUMATIC DIAGRAMS ...
Страница 44: ...SPARE PARTS LIST WITH TECHNICAL DRAWINGS ...