POSSIBLE MALFUNCTIONS AND THEIR REME
13
6.
POSSIBLE MALFUNCTIONS AND THEIR REMEDY
Malfunction
Drive
Remedy
Rapeseed/canola crop divider comes to stand-
still
electr.
Check fuse
Remedy cable breakage or faulty contacts
Replace toothed belt
Refill battery
Rapeseed/canola crop divider often runs slowly
electr.
Remedy faulty contacts at the battery, the relay, or the plugs
Realign bent knives
Control output of the generator
Fuse triggers often
electr.
Use cable with at least 6mm², connect directly to battery
Remedy faulty contacts at the battery, the relay, or the plugs
Realign bent knives
Loosen too tight knife guides
Repair worn sections at cables
Molten knife guides
Realign bent knives
Adjust knife guides less tight
Reduce too high speed;
550 - 600 Rev/min is correct
Bent knives
Rapeseed/canola crop divider is mounted too low at the cutting table
–
therefore ground contact