- 22 -
d)
Notices regarding the Setting of the Relay for the Conveying Worm Motor
K2 and E1:
Contactor with relay for conveying worm
Setting Range: 6 - 10 A
depending on motor output
10 - 16 A
depending on motor output
Attention!
E1 must be set to the respective current consumption muss auf die
(Ampere) of the conveying worm motor.
In the event of an overload of the motors, the relay E2 (conveying worm)
will shut down (yellow pin will stand out 2mm).
Re-start: Actuate the blue round button.
Red square button:
Manual triggering, if pulled upwards
Blue round button: Position H: Manual activation by actuation
Position A: Automatic activation after cooling down of thermal contact
Changeover from H to A:
At positioning H of the blue button, the same must be turned to A in actuated condition.
Содержание PKT 450
Страница 2: ......
Страница 4: ......
Страница 27: ... 27 Bild 1 7 8 50 5 10 6 4 4 3 11 13 Bild 2 9 12 7 8 27 Bild 3 ...
Страница 28: ... 28 Bild 4 15 13 11 4 9 10 14 4 4 7 6 9 Bild 5 ...
Страница 32: ... 32 Bild 11 Bild 12 61 56 63 60 62 57 52 55 60 62 51 58 59 53 30 54 29 28 27 30 25 26 ...
Страница 36: ......
Страница 60: ... 26 Image 1 7 8 50 5 10 6 4 4 3 11 13 Image 2 9 12 7 8 27 Image 3 13 ...
Страница 61: ... 27 Image 4 15 11 4 9 10 14 4 4 7 6 9 ...
Страница 65: ... 31 Image 11 61 63 60 62 Image 12 56 57 52 55 60 62 51 58 59 53 30 54 29 28 27 30 25 26 ...