- 18 -
Table 2
PKT 450: Flow Rates according to Nozzle Sizes (LUPROSIL®)
Nozzle Combination
Application Range Liters / Hour
1 x blue
30 – 140
1 x brown
40 – 220
blue x brown
60 – 360
white + brown
90 – 450
1 x TP 11020
108 – 460
TP 11020 + white
110 – 470
2 x TP 11020
120 – 480
Notice: „min.“: adjustmen screw right to the stop, to the extreme left.
„max.“: adjustmen screw right to the stop, close to the extreme right.
Notice: The output of the individual pumps [l/h] may vary. For this reason, the above stated
values can not be warranted for but must rather be regarded as average values in respect to all
pumps.
For small application quantities, it is possible to additionally order 2 orange nozzles XR
11001, the output of which is 40 l/h at one nozzle and approximately 10 to 80 l/h if two
nozzles are deployed (see Spare Parts List Item 45). At such small quantities, the display at
the flow measuring pipe is no longer sufficient.
A calibration must be performed!
Important !!! The above stated values only apply for LUPROSIL® or media with smilar
characteristics.
.
At LUPRO-GRAIN® and LUPROSIL NC, the flow values are dependant
of the media temperature.
Table 3 (
according to
BASF)
Application Quantity for Luprosil®
Application quantities for Luprosil® (in%) for moist cereal (whole grains ), all grain
types including sweet corn:
Moisture Content
Conservation Period, Months
in %
1
1-3
3-6
6-12
Up to 16
0,35
0,45
0,50
0,55
16-18
0,40
0,50
0,55
0,65
18-20
0,45
0,55
0,65
0,75
20-22
0,50
0,65
0,75
0,85
22-24
0,55
0,70
0,85
0,95
24-26
0,60
0,80
0,95
1,05
26-28
0,70
0,90
1,05
1,15
28-30
0,80
1,00
1,15
1,30
30-32
0,90
1,10
1,25
1,45
32-34
1,00
1,20
1,35
1,60
34-36
1,10
1,30
1,50
1,75
36-38
1,25
1,45
1,65
1,90
38-40
1,40
1,60
1,80
2,05
40-42
1,55
1,75
1,95
2,20
42-44
1,70
1,90
2,10
2,35
44-46
1,85
2,05
2,25
2,55
46-48
2,00
2,20
2,40
2,75
48-50
2,15
2,35
2,60
2,95
If it is intended to further convey the acid-preserved grain using a blower system directly after the acid treatment,
it is necessary to intermediately store the same for one hour. If the immediate conveying using a blower can not
be avoided, the application quantity recommended in the table must, according to BASF, be raised by at least 10
%.
Содержание PKT 450
Страница 2: ......
Страница 4: ......
Страница 27: ... 27 Bild 1 7 8 50 5 10 6 4 4 3 11 13 Bild 2 9 12 7 8 27 Bild 3 ...
Страница 28: ... 28 Bild 4 15 13 11 4 9 10 14 4 4 7 6 9 Bild 5 ...
Страница 32: ... 32 Bild 11 Bild 12 61 56 63 60 62 57 52 55 60 62 51 58 59 53 30 54 29 28 27 30 25 26 ...
Страница 36: ......
Страница 60: ... 26 Image 1 7 8 50 5 10 6 4 4 3 11 13 Image 2 9 12 7 8 27 Image 3 13 ...
Страница 61: ... 27 Image 4 15 11 4 9 10 14 4 4 7 6 9 ...
Страница 65: ... 31 Image 11 61 63 60 62 Image 12 56 57 52 55 60 62 51 58 59 53 30 54 29 28 27 30 25 26 ...