Automatic operation

In automatic operation the air conditioner selects the operation mode (cooling, dry, heating) according to

the room temperature when it starts.

The air conditioner will restart in the previous mode if automatic operation is resumed within 3 hours

from the switch-off.

Mode review. The computer checks and compares the room temperature regularly after the compres-

sor shuts off, and will adapt the operating mode. 

1.

Press the ON/OFF button

2.

Set the operation mode to Automatic “AUTO“, by pressing the operation

mode button

3.

Adjust the setting temperature by pressing the temperature setting buttons.

4.

Adjust the fan speed by pressing the fan speed button. When the mode is set

at “AUTO” the fan speed changes automatically.

G

NOTE

If the selected mode by Automatic operation does not suit you, set the operation mode (cooling,

dry, heating) with the operation mode button.

G

NOTE!

• If the unit operates in cooling or dry for a long time in high humidity (i.e., windows and doors

are opened), dew and water drops may form on the indoor unit. Be aware that falling drops of

water can damage your floor (e.g. carpet or parquet).

• If you set a low temperature for dry operation, you may feel the air flow is cold.

• During dry mode operation, the system performs the cooling operation until the room

temperature reaches 1~2°C above the setting temperature. Then it continues dry mode

operation intermittently with fan speed at “LO”, regardless of the designated speed.

• During dry operation, the indoor unit stops operating for 3 minutes when the room

temperature reaches the setting temperature.

• During the heating operation, the outdoor unit may frost and heating capacity may be

reduced. In this case, the unit stops its heating operation and conducts defrosting operation

automatically. During the defrosting operation, the fans of the indoor and outdoor units stop.

• Unless the heat exchanger gets warm enough, the air will not flow out to prevent cold air.

man_S17xx.qxd  06-02-2008  14:23  Pagina 11

Содержание S1731

Страница 1: ...S1731 S1735 S1753 4 1 TR OPERATING MANUAL GEBRUIKSAANWIJZING KULLANIM KILAVUZU 2 22 42...

Страница 2: ...uality product that if used responsibly will give you many years of pleasure Please read these instructions for use first in order to ensure the maximum life span of your airconditioner On behalf of t...

Страница 3: ...3 CONTENTS A Safety instructions 4 B Parts and functions 5 C Before operation 8 D Instructions for use 9 E Air filter 16 F Cleaning 16 G Trouble shooting 18 H Guarantee conditions 19 I Technical data...

Страница 4: ...move the plug of the unit from the wall socket when it is not in use A damaged power cord or plug must always be replaced by a recognised electrician or your supplier Do not operate or stop the aircon...

Страница 5: ...echin filter Inlet grill Vertical louver Horizontal louver Remote signal receiver Outlet The air flow direction can be adjusted with the vertical and horizontal louvers Beeping sound assures successfu...

Страница 6: ...ailure during operation operation status before power failure is memorized 3 4 minutes after power recovery the unit restarts automatically with previous operation status memorized 3 4 minutes is prot...

Страница 7: ...ON d TIME DISPLAY e TIMER MODE INDICATOR f TEMPERATURE INDICATION g TRANSMITTING INDICATION h TEMPERATURE SETTING BUTTONS i LOUVER BUTTON Air flow direction can be changed vertically with swing moveme...

Страница 8: ...quipped with a 3 in 1 air filter Photo catalytic catechin filter to clean the circulated room air Anti Dust Screening dust and large particles in the air Anti Odor Deodorizing bad smells from cigarett...

Страница 9: ...J button once 2 Adjust the time with buttons Holding a button changes time set ting in 10 minute intervals 3 Press the TIME ADJ button 3 times The present time appears on the dis play The setting is c...

Страница 10: ...eed changes automatically Cooling heating dry operation 1 Press the ON OFF button 2 Set the operation mode to Cooling Heating or Dry by pressing the operation mode button 3 Adjust the setting temperat...

Страница 11: ...mode button G NOTE If the unit operates in cooling or dry for a long time in high humidity i e windows and doors are opened dew and water drops may form on the indoor unit Be aware that falling drops...

Страница 12: ...conditioner is operating 1 Press the ON OFF button 2 Press the ionizer button To stop negative ion operation press the ionizer button Air flow adjustment Horizontal adjustment all models When the ON...

Страница 13: ...zontal louver will come to a halt if the vertical louver button is pressed once again Timer operation Before setting the timer confirm that the present time is set accurately Once you set the timer th...

Страница 14: ...ed for 2 seconds and then the present time appears Cancelling ON Timer Press the Timer fixing button ON The timer lamp of the indoor unit goes off OFF Timer Example Set the Off Timer to 10 p m Operati...

Страница 15: ...setting temperature drops 0 6 C after 30 minutes of Sleep Timer ON and drops 0 6 C again after 30 minutes of the first temperature drop Emergency and test operation Emergency Operation The emergency o...

Страница 16: ...is air conditioner is equipped with a 3 in 1 filter to clean the circulated room air a Anti Dust Screening dust and large particles in the air b Anti Odor Deodorizing bad smells from cigarette acetald...

Страница 17: ...the filters are completely behind the stopper If the filter is not attached correctly it may cause defects 4 Close the front panel Maintenance of the negative ion generator twice a year only S1731 S1...

Страница 18: ...igerant changes direction During the dry mode operation air may not flow out to prevent excessive cooling During the heating operation air does not flow out until the air is heated enough to prevent c...

Страница 19: ...guarantee 5 The guarantee is valid only when you present the original dated purchase invoice and if no modifica tions have been made 6 The guarantee is invalid for damage caused by neglect or by actio...

Страница 20: ...38 558 588 690 630 Voor ruimtes tot m3 75 100 85 110 130 150 Compressor type Rotary Rotary Rotary Ventilatorsnelheden 3 3 3 Thermostatisch bereik C 16 30 16 30 16 30 Werkingsgebied C 1 43 1 43 1 43 Ha...

Страница 21: ...vironmental information This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol It should only be serviced or dismantled by professional trained personnel This equipment con...

Страница 22: ...390 030 fax 358 9 4390 0320 email appliance appliance group com F FI IN N 4 UNITED KINGDOM Scott Brothers Ltd The Old Barn Holly House Estate Cranage Middlewich CW10 9LT UK tel 44 1606 837787 fax 44 1...