background image

 
 

SkyZhone 1604, 1404, 1204 Hardware 
Installation Guide 

 
 
 
 

For software version 1.2.x 

January 2008 
Document Part Number:  830-01809-01

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 

Содержание SkyZhone 1204

Страница 1: ...SkyZhone 1604 1404 1204 Hardware Installation Guide For software version 1 2 x January 2008 Document Part Number 830 01809 01...

Страница 2: ...ility non infringement or fitness for a particular purpose Further Zhone Technologies reserves the right to revise this publication and to make changes from time to time in the contents hereof without...

Страница 3: ...ipment FCC RF Exposure Requirements per OET 65 requires the SkyZhone platform to be mounted such that the general public does not come within 10 inches of the antennae ________________________________...

Страница 4: ...n this list Comet Part Number CFA 245W SR or having a gain greater than 5 dBi are strictly prohibited for use with this device The required antenna impedance is 50 ohms The 4 9 GHz band has been desig...

Страница 5: ...FOR INSTALLATION 21 Installation precautions 21 Selecting the locations 23 Specifications 23 INSTALLING THE SKYZHONE ACCESS POINT 27 Equipment needed for installation 27 Pole mounting kit 27 Wall mou...

Страница 6: ...ide Important Safety Instructions 49 EMI Notices 50 Supplier s Declaration of Conformity 52 Notice to Users of the Canadian Telephone Network 53 CE Marking 53 Contacting Global Service and Support 54...

Страница 7: ...th Carefully read and follow the instructions included in this document ______________________________________________________ Caution A caution alerts users to conditions or actions that could damage...

Страница 8: ...s and variables PLAIN UPPER CASE Used for environment variables Command Syntax Brackets indicate optional syntax Vertical bar indicates the OR symbol Related documentation Refer to the following publi...

Страница 9: ...File Transfer Protocol VoIP Voice over IP VoWi Fi Voice over Wifi VPN Virtual Private Network WEP Wired Equivalent Privacy Wi Fi Wireless Fidelity IEEE 802 11 wireless networking WMM Wi Fi Multimedia...

Страница 10: ...h America 877 ZHONE20 877 946 6320 Telephone International 510 777 7133 Internet www zhone com support If you purchased the product from an authorized dealer distributor Value Added Reseller VAR or th...

Страница 11: ...w The SkyZhone access point Models 1X04 are AC powered carrier class outdoor Wi Fi access points with 22 Mbps symmetric DSL backhaul to every unit The SkyZhone supports a variety of applications inclu...

Страница 12: ...4 GHz 802 11b g and 4 9 GHz 802 11a using two separate radios Four SHDSL lines with EFM Bonding are used for backhaul 120VAC power is required SkyZhone 1404 Wi Fi Access Point Supports wireless radio...

Страница 13: ...9 GHz radio operates in the licensed spectrum reserved for Public Safety users including city government police fire and EMT SkyZhone features The SkyZhone access points communicate with SkyZhone agg...

Страница 14: ...SHDSL card installed in a SkyZhone Aggregator Each SHDSL line card in the SkyZhone Aggregator provides 24 ports and each SkyZhone access point uses up to 4 ports The data rates for the SHDSL card are...

Страница 15: ...hone access point can be mounted on a pole at any angle between vertical and horizontal on a streetlight loop span or wall Wall Mounting Enclosure When wall mounted the SkyZhone access point may be co...

Страница 16: ...04 Hardware Install Guide Cables The SkyZhone Port Connectors The port connectors are located on either side of the SkyZhone unit Figure 4 shows the SkyZhone access point port locations Figure 4 SkyZh...

Страница 17: ...support line power The four SHDSL pair are data only ____________________________________________________________ Note The mechanical configuration SOCKET vs PLUG of the SHDSL POE Console and AC Power...

Страница 18: ...ndard external POE cable that mates with this connector This is to avoid surges on these unprotected pins Therefore a special cable is required to access the Console pins Since the console pins are no...

Страница 19: ...the AC Power PLUG cable Table 5 AC Power PLUG connector pinouts Pin Signal Color 1 Neutral White 2 No connection 3 Line Black GND Chassis GND Green Grounding Proper grounding must be complete before...

Страница 20: ...20 SkyZhone 1604 1404 1204 Hardware Install Guide...

Страница 21: ...t for this purpose Connect a length of 10 AWG solid bare copper wire to the grounding lug and firmly tighten the grounding screw see Figure 20 Connect the other end of the grounding wire to a grounded...

Страница 22: ...hen the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the user manual may incr...

Страница 23: ...que due to the physical environment Before installing each SkyZhone access point perform a site survey to determine the optimum placement of units for maximum range coverage and network performance Th...

Страница 24: ...y and Dust IP66 NEMA4X IEC 60529 MANAGEMENT Management Interfaces WEB I F Command Line I F SNMPv2 TR 069 Management Access HTTPS SSH TR 069 Mgmt Access Security RADIUS password authentication Wi Fi Ac...

Страница 25: ...Data Rates Mbps 2 4 GHz Wireless Channels 1 11 b 11 5 5 2 1 g 54 48 36 24 18 12 9 6 4 9 GHz Wireless 4 96 GHz and 4 98 GHz center freq a 54 48 36 24 18 12 9 6 Operating Distance Over 18 000 feet AWG...

Страница 26: ...Mbps Number of Ports 1 Output Power 48V DC maximum 5W Data Path VLAN support IEEE 802 1Q Traffic Prioritization IEEE 802 1p 802 11e IP TOS Number of Priority Queues 4 Traffic Classification Based on p...

Страница 27: ...point must always be mounted with the top of the unit horizontal and level It is best to mount the SkyZhone access point to a metal structure The metal mounting brackets are designed to make good con...

Страница 28: ...ough the metal bracket plastic cover and into your wall s surface Wall mount kit without plastic cover The SkyZhone access point wall mount kit without plastic cover contains the following items One w...

Страница 29: ...ss point to any pipe or pole 1 Attach screw clamp bands to the pole mounting plate by threading them through the slots on the mounting plate The slots are for either horizontal or vertical mounting on...

Страница 30: ...late strapped around a pole 3 Tighten and if necessary trim off any excess tension band 4 Secure the mounting bracket to the pole see Figure 11 on page 31 The SkyZhone shelf is attached to the poll mo...

Страница 31: ...are connected to the top of the unit The two shorter antennas are mounted to the bottom of the unit The antennas are not interchangeable It is critical that the longer antennas are on the top and the...

Страница 32: ...if needed _________________________________________________________ Note This previous procedure showed the SkyZhone station being mounted to a vertical pole The same instructions apply to the install...

Страница 33: ...he cover is used to hide the unit for aesthetic purposes This cover can be painted which allows the unit to blend in with the building Figure 12 displays a fully assembled SkyZhone with its cover Figu...

Страница 34: ...rely ______________________________________________________ 1 Find a flat surface that is at least 24 inches tall and 36 inches wide 2 Drill the holes in the wall to align with the corresponding holes...

Страница 35: ...sing to ensure in proper orientation Use a 1 4 inch drill masonry bit to install a 1 inch plastic insert to secure the cover and the aluminum frame to the concrete wall with the appropriate screws Fig...

Страница 36: ...wall mounting bracket with the 4 four tamper resistant screws provided in the installation kit through the holes on the front of the unit _________________________________________________________ WAR...

Страница 37: ...SkyZhone 1604 1404 1204 Hardware Installation Guide 37 Figure 17 Wall Mount Kit Final Assembly Figure 18 Example of a wall mounted SkyZhone...

Страница 38: ...ompleted before applying AC power to the SkyZhone unit ______________________________________________________ Connect a length of 10 AWG solid bare copper wire to the wire grounding lug of the unit an...

Страница 39: ...settings for the network are IP address 10 108 14 218 Subnet mask 255 255 255 0 Broadcast Address 10 108 14 255 Default gateway 10 108 14 254 Use the following three commands to configure VLAN managem...

Страница 40: ...config vlan vlanconfig addport interface eth1 vlanid 2 untagged config vlan portdefaults default pvid vlanport eth1 pvid 2 3 Configure the management address In this example the device address is 10...

Страница 41: ...9 GHz SkyZhone 1424 Single 4 9 GHz Login admin admin admin Password zhone zhone zhone WLAN 0 2 4GHz 2 4 GHz N A WLAN 1 N A 4 9 GHz 4 9 GHz Default VLANs 0 internal 1 data 7 management 0 internal 1 dat...

Страница 42: ...346 WLAN 1 DTIM period N A 2 2 WLAN 1 Preamble Type N A Long Long WLAN 1 Antenna Power Attenuation N A 2 dB 2 dB WLAN 1 Antenna Select N A auto Auto System Configuration Host Name SkyZhone SkyZhone Sk...

Страница 43: ...ace Alias Bridge VLAN 1 Bridge VLAN 1 Bridge VLAN 1 LAN IP 0 0 0 0 0 0 0 0 0 0 0 0 Netmask 0 0 0 0 0 0 0 0 0 0 0 0 Broadcast Address 0 0 0 0 0 0 0 0 0 0 0 0 Interface Name brvlan7 brvlan7 brvlan7 Inte...

Страница 44: ...44 SkyZhone 1604 1404 1204 Hardware Install Guide...

Страница 45: ...erification as to whether it is operating correctly or if it needs to be replaced Figure 20 LED Location The following table describes the possible states of the LED light Color Operation Description...

Страница 46: ...46 SkyZhone 1604 1404 1204 Hardware Install Guide...

Страница 47: ...nit for this purpose Connect a length of 10 AWG solid bare copper wire to the grounding lug and firmly tighten the grounding screw see Figure 20 Connect the other end of the grounding wire to a ground...

Страница 48: ...enerates uses and can radiate radio frequency energy and if not installed and used in accordance with the user manual may increase the potential for harmful interference to radio communications This w...

Страница 49: ...lightning strikes and surges A copper ground lug is provided on the unit for this purpose Connect a length of 10 AWG solid bare copper wire to the grounding lug and firmly tighten the grounding screw...

Страница 50: ...in wet locations unless the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interfac...

Страница 51: ...nterference to other users the antenna type and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that permitted for successful communication Opera...

Страница 52: ...4 bearing the FCC identification numbers PJZSZ1224 PJZSZ1424 PJZSZ1624 complies with the Federal Communications Commission s FCC Rules and Regulations pursuant to part 15 subpart C 14 247 part 15 Clas...

Страница 53: ...the Canadian Telephone Network NOTICE This equipment has been certified to ITU T G991 2 CE Marking When the product is marked with the CE mark on the equipment label a supporting Declaration of Confor...

Страница 54: ...of your product or if you want to return a product for repair under warranty contact GSS The contact information is as follows E mail support zhone com Telephone North America 877 ZHONE20 Telephone In...

Отзывы: