Reference Guide
B-1
Appendix B
Error Messages
B.1
Error Messages Introduction
This appendix lists the Integrated Access System error messages. One of these messages may
appear at the bottom of the screen when you enter a command, indicating that the system did
not perform the requested action. This condition may have been caused by an operator error,
absence of a card in the system, or other condition. If an error message appears, take the
appropriate corrective action. For convenience, the system error messages are listed
alphabetically.
‘0000’ invalid for E, reverted to original.
The sequence 0000 is not a valid ABCD signaling sequence on E1 links. Choose a different
ABCD sequence for E1 signaling conversion to/from T1 format.
A name must be assigned to Circuit ID field.
You must enter a name for the circuit before attempting this operation. Go to the Circuit ID
field, type the desired name, and save it.
ADPCM card is not installed or rdnt.
An ADPCM card is not present in the system, or you chose a redundant ADPCM card for data
compression. Install an ADPCM card, or selected a non-redundant card.
Alarm Card can’t be active with dialing.
An External Alarm card cannot be used when HSU cards are programmed for ISDN dialing.
Remove this card.
All available PVCs are already taken.
The number of PVCs available on the FRAD Card Main Screen has been exceeded by the
number of PVCs assigned on the PVC Screen. Assign a number of PVCs on the PVC Screen
that is lower than the quantity chosen in the Main Screen.
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...