Server Cards
20-1
Analog Bridging Server Card
Introduction
Chapter 20
Analog Bridging Server Card
20.1
Introduction
This chapter provides installation, configuration, and troubleshooting information for the
Analog Bridging Server Card, (BRIDGE).
20.2
Analog Bridging Server Card Description
(8000-BRIDGE)
The Analog Bridging Server Card is a plug-in server card which allows the analog voice band
signals from up to thirty two voice circuits to be combined (bridged). In the case of the IMACS
application, each analog circuit is a DS0 channel carrying analog traffic from an access card
port such as a FXS, 4W E&M, 2W E&M or from a WAN port. Although this traffic originates
as an analog signal, it is bridged digitally in the Analog Bridge card after it has been digitalized
into a DS0. The bridge itself is set up via the provisioning interface on the IMACS
maintenance terminal. Once the bridge is set up, the circuits remain permanently bridged until
the provisioning is changed. There is no supervision (on/hook or off/hook) or signaling (digit
dialing) involved with circuits that are bridged. End-users can not dynamically add or delete
themselves from the bridge, making this a permanent telephone conference bridge with no
dynamic end-user control.
The BRIDGE Analog Bridging card can support up to 240 total DS0 circuits. There are 80
bridges available, and each bridge is capable of joining 32 subscribers. Echo cancellation and
half duplex options are available.
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...