System Cards
9-47
WAN Card
WAN Card Error Messages
9.5
WAN Card Error Messages
Refer to Appendix B in the System Reference Guide for further information on Error
Messages regarding this card.
9.6
WAN Card Troubleshooting
The WAN card (or a T1 or E1 port on it) may be faulty if a CGA-Red alarm is in progress on
either port of the card. This alarm occurs if the incoming network signal is lost, or if the WAN
port is out of frame with that signal. To isolate the trouble, proceed as follows:
1. See if similar alarms are also present on any other T1/E1 lines and WAN cards in the
system. If so, the trouble may be with the Interface card, which connects the T1 and E1
signals from the WAN cards to the external network. If the trouble is only on one T1 or
E1 line connected to the WAN card, continue with step 2.
2. Perform a local T1 or E1 signal loopback toward the CPE, and see if the CGA alarm
clears after about 10 to 30 seconds. If it does, the WAN card is good; go to step 3.
Otherwise, go to step 4.
3. Check the local network equipment receiver, cabling to the Interface card at the local
system, and the far-end system or network transmitter.
4. Replace the WAN card with an identical WAN card. Be sure to install the same types
of plug-in modules and that the jumpers on the cards are identical on the new WAN card
before plugging it in.
5. If the WAN card is determined to be faulty, replace it and return the faulty unit for repair
to the location specified by your distributor.
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...