9-32
System Cards
Model No.
Running Head
WAN Card User Screens and Settings
WAN Card
Table 9-7. E1 Screen Option Settings and Defaults
Notes:
1. AIS/ALM will show none until the GROUP is selected.
2. The up and down arrow keys are used to scroll through the loopback address values.
3. The Farstat registers will not work properly for E1 operations unless the c-sa4 option
is selected for the COM/NMS RP parameter.
4. If there is no redundant WAN card in the appropriate slot, the only option that will
appear is n/a.
5. Selection of GROUP is a two-step process. After identifying the group number (1-4),
the user must select the secondary group (A, B or C).
STATE
In the standby state, the WAN port is electrically disconnected from the external network. Set
State setting to stdby (standby) when setting up your WAN links, then changes it to actv
(active) when starting normal operations.
MODE
In cross-connect systems, Mode automatically defaults to xcon.
Parameter
User Options
Notes
Default
STATE
stdby actv
stdby
MODE
xcon
xcon
FRAME
crc d-frm
crc
TS16
cas ccs nos
cas
EVEN BIT
norm inv
norm
AIS/ALM
none tcodr
1
none
LINE LB
off on
off
LOCAL LB
off on
off
CH LB
off clr
off
LB ADDR
01-31 (user-selectable)
2
01
LB GEN
off llb plb nlb
off
COM/NMS RP
none c-sa4 c-br7 e-sa4
(c-fdl)
3
none
EER THRHD
10e-4 through 10e-9 none
10e-4
RDNT RULES
n/a none OOS CGA
4
none
GROUP
none 1 2 3 4
5
none
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...